Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM150RSD120
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
150 Amperes/1200 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
IGBT Inverter Sector
Collector Cutoff Current
Diode Forward Voltage
Collector-Emitter Saturation Voltage
Inductive Load Switching Times
ICES
VEC
VCE(sat)
ton
trr
tC(on)
toff
tC(off)
VCE = VCES, Tj = 25°C, VD = 15V
—
VCE = VCES, Tj = 125°C, VD = 15V
—
-IC = 150A, VD = 15V, VCIN = 15V
—
VD = 15V, VCIN = 0V, IC = 150A,
—
Pulsed, Tj = 25°C
VD = 15V, VCIN = 0V, IC = 150A,
—
Pulsed, Tj = 125°C
0.5
VD = 15V, VCIN = 0 ~ 15V
—
VCC = 600V, IC = 150A
—
Tj = 125°C, Inductive Load
—
—
IGBT Brake Sector
Collector Cutoff Current
FWDi Forward Voltage
Collector-Emitter Saturation Voltage
Control Sector
ICES
VFM
VCE(sat)
VCE = VCES, Tj = 25°C, VD = 15V
—
VCE = VCES, Tj = 125°C, VD = 15V
—
IF = 50A
—
VD = 15V, VCIN = 0V, IC = 50A,
—
Pulsed, Tj = 25°C
VD = 15V, VCIN = 0V, IC = 50A,
—
Pulsed, Tj = 125°C
Over Current Trip Level Inverter Part
OC
(VD = 15V)
Over Current Trip Level Brake Part
OC
Short Circuit Trip Level Inverter Part
SC
Short Circuit Trip Level Brake Part
Tj = 25°C
228
Tj = 125°C
200
-20°C ≤ Tj ≤ 125°C, VD = 15V
75
-20°C ≤ Tj ≤ 125°C, VD = 15V
—
—
Over Current Delay Time
Over Temperature Protection (VD = 15V)
(Lower Arm)
Supply Circuit Under Voltage Protection
toff(OC)
OT
OTR
UV
VD = 15V
—
Trip Level
111
Reset Level
—
Trip Level
11.5
(-20 ≤ Tj ≤ 125°C)
Circuit Current
Input ON Threshold Voltage
Input OFF Threshold Voltage
Fault Output Current*
Minimum Fault Output Pulse Width*
UVR
ID
VCIN(on)
VCIN(off)
IFO(H)
IFO(L)
tFO
Reset Level
—
VD = 15V, VCIN = 15V, VN1-VNC
—
VD = 15V, VCIN = 15V, VXP1-VXPC
—
Applied between UP-VUPC, VP-VVPC, 1.2
WP-VWPC, UN, VN, WN, Br -VNC
1.7
VD = 15V, VCIN = 15V
—
VD = 15V, VCIN = 15V
—
VD = 15V
1.0
*Fault output is given only when the internal OC, SC, OT and UV protections schemes of either upper or lower arm device operate to protect it.
Typ.
—
—
2.5
2.4
2.1
1.0
0.15
0.4
2.5
0.7
—
—
2.5
2.65
2.60
410
—
—
540
144
10
118
100
12.0
12.5
60
15
1.5
2.0
—
10
1.8
Max. Units
1.0
mA
10
mA
3.5
Volts
3.2
Volts
2.8
Volts
2.5
µS
0.3
µS
1.0
µS
3.5
µS
1.2
µS
1.0
mA
10
mA
3.5
Volts
3.30 Volts
3.25 Volts
— Amperes
— Amperes
— Amperes
— Amperes
— Amperes
—
µS
125
°C
—
°C
12.5 Volts
—
Volts
82
mA
20
mA
1.8
Volts
2.3
Volts
0.01
mA
15
mA
—
mS
3