I/O capacitance
Item
Symbol Test conditions Min.
Input capacitance
CIN
VIN = 0V
—
I/O capacitance
CI/O
VI/O = 0V
—
Note) This parameter is sampled and is not 100% tested.
(Ta = 25°C, f = 1MHz)
Typ. Max. Unit
—
8 pF
—
10 pF
AC Characteristics
• AC test conditions
(Ta = –25 to +85°C)
Item
Input pulse high level
Conditions
VCC = 2.7 to 3.6V VCC = 3.3V ± 0.3V
VIH = 2.4V
VIH = 2.2V
Input pulse low level
Input rise time
Input fall time
VIL = 0.4V
tr = 5ns
tf = 5ns
VIL = 0.6V
tr = 5ns
tf = 5ns
Input and output reference level
-10LLX
Output load conditions
-12LLX
1.4V
1.4V
CL∗1 = 100pF, 1TTL CL∗1 = 30pF, 1TTL
CL∗1 = 100pF, 1TTL CL∗1 = 100pF, 1TTL
∗1 CL includes scope and jig capacitances.
• Test circuit
TTL
CL
–4–