MITSUBISHI INTELLIGENT POWER MODULES
PM75RVA060
FLAT-BASE TYPE
INSULATED PACKAGE
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Control Sector
Over Current Trip Level Brake Part
OC
Short Circuit Trip Level Inverter Part
SC
Short Circuit Trip Level Brake Part
-20°C ≤ Tj ≤ 125°C, VD = 15V
-20°C ≤ Tj ≤ 125°C, VD = 15V
39
—
115
—
—
94
Short Circuit Current Shut-off Time
Over Temperature Protection
toff(SC)
OT
VD = 15V
Trip Level
—
10
100
110
(VD = 15V, Lower Arm)
OTr
Supply Circuit Under Voltage Protection
UV
Reset Level
Trip Level
85
95
11.5
12.0
(-20°C ≤ Tj ≤ 125°C)
UVr
Reset Level
—
Circuit Current
ID
VD = 15V, VCIN = 15V, VN1-VNC
—
VD = 15V, VCIN = 15V, VXP1-VXPC
—
Input ON Threshold Voltage
Vth(on)
Applied between UP-VUPC, VP-VVPC, 1.2
Input OFF Threshold Voltage
Vth(off)
WP-VWPC, UN · VN · WN · Br-VNC
1.7
Fault Output Current
IFO(H)
VD = 15V, VFO = 15V*
—
IFO(L)
VD = 15V, VFO = 15V*
—
Minimum Fault Output Pulse Width
tFO
VD = 15V*
1.0
* Fault output is given only when the internal SC, OT, and UV protections circuits of either an upper-arm or a lower-arm device operate to protect it.
12.5
44
13
1.5
2.0
—
10
1.8
Max. Units
— Amperes
— Amperes
— Amperes
—
µs
120
°C
105
°C
12.5 Volts
—
Volts
60
mA
18
mA
1.8
Volts
2.3
Volts
0.01
mA
15
mA
—
ms
Sep.1998