Philips Semiconductors
Frequency Shift Keying (FSK) receiver
Preliminary specification
UAA3202M
TEST INFORMATION
Tuning procedure for AC tests
1. Turn on the signal generator (fi = 433.92 MHz; no modulation; RF input level = −60 dBm).
2. Tune C6 (RF stage input) to obtain a peak voltage on test point A (see Fig.11).
3. Turn on modulation (fi = 433.92 MHz; fmod = 250 Hz square wave; ∆f = 25 kHz; RF input level = −60 dBm).
4. Check that data is appearing on the data output (pin 11) and proceed with the AC tests.
AC test conditions
Table 2 Test signals
The reference signal level Pref for the following tests is defined as the minimum input level in dBm to give a
BER ≤ 3 × 10−2 (e.g. 15 bit errors per second for 500 bits/s).
TEST
SIGNAL
1
2
3
FREQUENCY
(MHz)
433.92
433.92
433.82
DATA SIGNAL
250 Hz square wave
−
−
MODULATION
FM (FSK)
no modulation
no modulation
FREQUENCY
DEVIATION
25 kHz
−
−
Table 3 Test results
P1 is the maximum available power from signal generator 1 at the input of the test board; P2 is the maximum available
power from signal generator 2 at the input of the test board.
TEST
Sensitivity into pin MXIN
(see Fig.6)
Maximum input power
(see Fig.6)
Receiver turn-on time; note 1
Intercept point (mixer + PMA)
see note 2 and Fig.7
Spurious radiation see note 3
and Fig.8
1 dB compression point
(mixer + PMA) see note 2
and Fig.9
GENERATOR
1
2
modulated test
−
signal 1; P1 ≤ −94 dBm
modulated test
−
signal 1; P1 ≥ −30 dBm
(minimum Pmax)
test signal 1;
−
P1 = Pref + 10 dB
test signal 3;
P1 = −55 dBm
−
test signal 2;
P2 = P1
−
test signal 3;
−
P11 = −70 dBm;
P12 = −45 dBm
(minimum P1dB)
RESULT
BER ≤ 3 × 10−2
(e.g. 15 bit errors per second for 500 bits/s)
BER ≤ 3 × 10−2
(e.g. 15 bit errors per second for 500 bits/s)
check that the first 10 bits are correct; error
counting is started 10 ms after PWD
switched to operating mode: ON
IP3 = P1 + 1⁄2 × IM3 (dB); IP3 ≥ −38 dBm
no spurious radiation (25 MHz − 1 GHz)
with level higher than −60 dBm
(maximum Pspur)
(Po1 + 70 dB) − [Po2 + 45 dB (minimum
P1 dB)] ≤ 1 dB, where Po1, Po2 is the output
power for test signals with P11 or P12,
respectively
Notes
1. The power-down voltage VPWD alternates between operating mode ON (100 ms) and OFF (100 ms); see Fig.5.
2. Probe of spectrum analyzer connected to test point A.
3. Spectrum analyzer connected to the input of the test board.
1997 Aug 12