VKP60xTC
60 Watt Triple Output
Half Brick DC/DC Converter
TYPICAL PERFORMANCE CURVES
Specifications are at TCASE = +40°C nominal input voltage, nominal load, recommended external components applied, unless otherwise specified.
(Refer to Application Note DCAN-9 at www.murata-ps.com)
EFFICIENCY vs TEMPERATURE
T = +40°C, nominal input voltage, nominal load, recommended external
CASE
components applied, unless otherwise specified.*
Case Temperature (°C)
www.murata-ps.com
ABSOLUTE MAX. RATINGS
Output Short-Circuit
Duration
Baseplate Temperature
Lead Temperature
(soldering, 10 seconds max)
Storage Temperature
Input to Output Isolation
Continuous
+100°C
+300°C
+125°C
1500 VDC
Technical inquiries - email: sales@murata-ps.com, tel: 508 339 3000
TDC_VKP60xTC.B01 Page 5 of 7