IDT79RC4650™
DC Electrical Characteristics — Commercial Temperature range—R4650
(VCC = 5.0±5%, TCASE = 0°C to +85°C)
Parameter
VOL
VOH
VOL
VOH
VIL
VIH
IIN
CIN
COUT
I/OLEAK
R4650 100MHz
R4650 133MHz
Minimum Maximum Minimum Maximum
Conditions
—
0.1V
VCC - 0.1V
—
—
0.4V
2.4V
—
—
0.1V
VCC - 0.1V
—
—
0.4V
2.4V
—
|IOUT| = 20uA
|IOUT| = 4mA
–0.5V
2.0V
—
—
0.2VCC
VCC + 0.5V
±10uA
10pF
–0.5V
2.0V
—
—
0.2VCC
VCC + 0.5V
±10uA
10pF
—
—
0 ≤ VIN ≤ VCC
—
—
10pF
—
10pF
—
—
20uA
—
20uA
Input/Output Leakage
Power Consumption—R4650
Parameter
System Condition:
ICC standby
active,
64-bit bus
option
R4650 100MHz
Typical1
Max
100/50MHz
—
—
700 mA2
75 mA2
150 mA2
900 mA2
800 mA2
1000 mA2
R4650 133MHz
Typical1
Max
133/67MHz
—
—
900 mA2
100 mA2
200 mA2
950 mA2
1000 mA2
1100 mA2
800 mA2
1200 mA4
1000 mA2
1350 mA4
1. Typical integer instruction mix and cache miss rates, Vcc 3.3V, TA=25×.
2. These are not tested. They are the results of engineering analysis and are provided for reference only.
3. Guaranteed by design.
4. These are the specifications IDT tests to insure compliance.
Conditions
—
CL = 0pF3
CL = 50pF
CL
No
= 0pF
SysAd
activity3
CL = 50pF
R4x00 compatible writes,
TC = 25oC
CL = 50pF
Pipelined writes or write re-
issue,
TC = 25oC
13 of 25
April 10, 2001