AMP04
120
BASED ON 300 UNITS
100 3 RUNS
80
TA = 25؇C
VS = 5V
VCM = 2.5V
60
40
20
0
–200 –160 –120 –80 –40 0 40 80 120 160 200
INPUT OFFSET VOLTAGE – V
Figure 16. Input Offset (VIOS) Distribution @ 5 V
120
BASED ON 300 UNITS
100 3 RUNS
80
TA = 25؇C
VS = 15V
VCM = 0V
60
40
20
0
–0.5 –0.4 –0.3 –0.2 –0.1 0
0.1 0.2 0.3
INPUT OFFSET VOLTAGE – mV
0.4 0.5
Figure 19. Input Offset (VIOS) Distribution @ ±15 V
120
300 UNITS
100
VS = 5V
VCM = 2.5V
80
60
40
20
0
0 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
TCVIOS – V/؇C
Figure 17. Input Offset Drift (TCVIOS) Distribution @ 5 V
120
300 UNITS
100
VS = 15V
VCM = 0V
80
60
40
20
0
0 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
TCVIOS – V/؇C
Figure 20. Input Offset Drift (TCVIOS) Distribution @ ±15 V
120
BASED ON 300 UNITS
100 3 RUNS
80
TA = 25؇C
VS = 5V
VCM = 2.5V
60
40
20
0
–2.0 –1.6 –1.2 –0.8 –0.4 0
0.4 0.8 1.2 1.6 2.0
OUTPUT OFFSET – mV
Figure 18. Output Offset (VOOS) Distribution @ 5 V
120
BASED ON 300 UNITS
100 3 RUNS
80
TA = 25؇C
VS = 15V
VCM = 0V
60
40
20
0
–5 –4 –3 –2 –1 0 1 2 3 4 5
OUTPUT OFFSET – mV
Figure 21. Output Offset (VOOS) Distribution @ ±15 V
–12–