Electrical and Mechanical Characteristics, Tj = 25 °C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Control Sector
Over Current Trip Level
Short Circuit Trip Level
Over Current Delay Time
Over Temperature Protection
Supply Circuit Under Voltage Protection
Supply Voltage
Circuit Current
Input ON Threshold Voltage
Input OFF Threshold Voltage
PWM Input Frequency
Fault Output Current
Minimum Fault Output Pulse Width
OC
SC
toff(OC)
OT
OTR
UV
UVR
VD
ID
VCIN(on)
VCIN(off)
fPWM
IFO(H)
IFO(L)
tFO
-20°C ≤ Tj ≤ 125°C, VD= 15V
-20°C ≤ Tj ≤ 125°C, VD= 15V
VD = 15V
Trip Level
Reset Level
Trip Level
Reset Level
Applied between VUP1-VUPC,
VVP1-VVPC, VWP1-VWPC, VN1-VNC
VD = 15V, VCIN = 15V, VN1-VNC
VD = 15V, VCIN = 15V, VXP1-VXPC
Applied between
UP, VP, WP, UN, VN, WN
3-Ø Sinusoidal
VD = 15V, VFO = 15V
VD = 15V, VFO = 15V
VD = 15V
22
–
–
100
–
11.5
–
13.5
–
–
1.2
1.7
–
–
–
1.0
Typ.
37
56
10
110
90
12.0
12.5
15.0
18
7
1.5
2.0
15
–
10
1.8
Max. Units
– Amperes
– Amperes
–
µS
120
°C
–
°C
12.5 Volts
–
Volts
16.5 Volts
25
mA
10
mA
1.8
Volts
2.3
Volts
20
kHz
0.01
mA
15
mA
–
mS
507