CXA1853AQ
No.
Item
Symbol
Measurement conditions
Min. Typ. Max. Unit
(See “White Side Gamma Measurement Method”.)
Set V45 = VI, V23 = 1.6V, V71 = 5.0V, V74 = 3.3V,
R gamma white side
170 breakpoint sub adjustment ∆PGWR1
range (1)
SW41 → ON and V41 = 1.6V.
Then measure the gamma breakpoint at TP16,
and label the non-inverted side as PGWGT and the
inverted side as PGWGTA.
— –0.3 –0.15 V
Next, measure the gamma breakpoint at TP15 with
SW75 → ON and V75 = 5.0, and label the non-
inverted side as PGWRN and the inverted side as
PGWRNA.
R gamma white side
171 breakpoint sub adjustment ∆PGWR2
range (2)
∆PGWR1 = PGWRN (A) – PGWGT (A)
Next, measure the gamma breakpoint at TP15 with
V75 = 1.6V, SW1 → ON and V1 = 2.3V, and label 0.15 0.3
—
V
the non-inverted side as PGWRM and the inverted
side as PGWRMA.
∆PGWR2 = PGWRM (A) – PGWGT (A)
(See “White Side Gamma Measurement Method”.)
B gamma white side
172 breakpoint sub adjustment ∆PGWB1
Set V45 = VI, V23 = 1.6V, V71 = 5.0V, V74 = 3.3V,
SW41 → ON, V41 = 1.6V, SW76 → ON and
V76 = 5.0V.
—
–0.3 –0.15
V
range (1)
Then measure the gamma breakpoint at TP17,
and label the non-inverted side as PGWBN and the
inverted side as PGWBNA.
∆PGWB1 = PGWBN (A) – PGWGT (A)
B gamma white side
173 breakpoint sub adjustment ∆PGWB2
range (2)
Next, measure the gamma breakpoint at TP17 with
V75 = 1.6V, SW1 → ON and V1 = 2.3V, and set 0.15 0.3
the non-inverted side as PGWBM and the inverted
—
V
side as PGWBMA.
∆PGWB2 = PGWBM (A) – PGWGT (A)
WHT LIM standard voltage
174
value
VWT
WHT LIM adjustment
175 range (1)
∆VW1
176 WHT LIM adjustment
range (2)
∆VW2
Set V45 = 5.0V, V42 = 0V, V54 = 0V and input
SG1 (0dB) to (TEST IN).
Label the non-inverted output amplitudes (black to
white) at TP15, TP16 and TP17 as VWRLT, VWGLT 1.7 2.0 2.3 V
and VWBLT, and the inverted output amplitudes as
VWRLTA, VWGLTA and VWBLTA, respectively.
Next, label the non-inverted output amplitudes
(black to white) at TP15, TP16 and TP17 with
SW41 → ON and V41 = 5.0V as VWRLN, VWGLN
and VWBLN, and the inverted output amplitudes as
VWRLNA, VWGLNA and VWBLNA, respectively.
Next, label the non-inverted output amplitudes
(black to white) at TP15, TP16 and TP17 with
— –1.7 –1.3 V
V41 = 1.6V as VWRLM, VWGLM and VWBLM, and the
inverted output amplitudes as VWRLMA, VWGLMA
and VWBLMA, respectively.
VWT = VWRLT (A), VWGLT (A),
VWBLT (A)
∆VW1 = VWRLN (A) – VWRLT (A)
= VWGLN (A) – VWGLT (A)
= VWBLN (A) – VWBLT (A)
2.4 2.8 — V
∆VW2 = VWRLM (A) – VWRLT (A)
= VWGLM (A) – VWGLT (A)
VWBLM (A) – VWBLT (A)
– 21 –