Remote Temperature Sensor
with SMBus Serial Interface
Table 3. Command-Byte Bit Assignments
REGISTER
COMMAND
POR STATE
FUNCTION
RFU
00h
N/A
Reserved for future use
RRTE
01h
0000 0000*
Read remote temperature; returns latest temperature
RSL
02h
N/A
Read status byte (flags, busy signal)
RCL
03h
0000 1000
Read configuration byte
RCRA
04h
0000 0111
Read conversion rate byte (not supported by MAX1618)
RFU
05h
N/A
Reserved for future use
RFU
06h
N/A
Reserved for future use
RRHI
RRLS
WCA
07h
0111 1111
Read remote THIGH limit
08h
1100 1001
Read remote TLOW limit
09h
N/A
Write configuration byte
WCRW
0Ah
N/A
Write conversion rate byte (not supported by MAX1618)
RFU
0Bh
N/A
Reserved for future use
RFU
0Ch
N/A
Reserved for future use
WRHA
0Dh
WRLN
0Eh
OSHT
0Fh
N/A
Write remote THIGH limit
N/A
Write remote TLOW limit
N/A
One-shot command
MFGID
FEh
01001101
Read manufacturer ID code
DEVID
FFh
00000010
Read device ID code
*If the device is in hardware standby mode at POR, the temperature register reads 0°C.
Table 4. Configuration-Byte Bit
Assignments
BIT
7
(MSB)
NAME
MASK
POR
STATE
0
FUNCTION
Masks all ALERT interrupts
when high.
Standby mode control bit. If
high, the device immediately
6
RUN/
STOP
0
stops converting and enters
standby mode. If low, the
device converts in either
one-shot or timer mode.
ALERT pin polarity control in
5
POL
0
thermostat mode.
0 = active low
1 = active high
4
THERM
0
Enables thermostat mode
when high.
Enables diode bias current.
0 (Logic Low) = 5µA to 50µA
3
ID
1
(typ)
1 (Logic High) = 10µA to
100µA (typ)
2 to 0 RFU
0
Reserved for future use.
Table 5. Status-Byte Bit
Assignments
BIT
NAME
FUNCTION
7
(MSB)
BUSY
A high indicates that the ADC is busy
converting.
6, 5
RFU
Reserved for future use (returns 0).
A high indicates that the remote high-
4
RHIGH*
temperature alarm has activated. In
thermostat mode, this bit is always in
the same state as the ALERT output.
A high indicates that the remote low-
3
RLOW*
temperature alarm has activated. In
thermostat mode, this bit is always
zero.
A high indicates a remote-diode fault
2
DIODE (open-circuit, shorted diode, or DXP
short to GND).
1, 0
(LSB)
RFU
Reserved for future use (returns 0).
*In ALERT mode, the HIGH and LOW temperature alarm flags
stay high until cleared by POR or until the status byte register
is read.