DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX1747EUP 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
生产厂家
MAX1747EUP
MaximIC
Maxim Integrated MaximIC
MAX1747EUP Datasheet PDF : 13 Pages
First Prev 11 12 13
Triple Charge-Pump TFT LCD
DC-DC Converter
MAX1747
OSC
SUPP
C3
DRVP
VSUPP = 2.7V TO 13V
D1
D2
MAX1747
OSC
IN
SHDN
VON = VIN
CIN
RFREQ
VREF
1.25V
GND
FBP
PGND
R3
R4
VPOS
C4
VPOS = [1 + (R3/R4)] VREF
VREF = 1.25V
Figure 4. Positive Charge-Pump Block Diagram
GND
RFREQ = kFREQ (VON - 0.7V)/fOSC
RFREQ IS IN k, kFREQ IS 45.5MHz/mA,
AND fOSC IS IN MHz.
Figure 5. Frequency Adjustment
in the Typical Operating Characteristics). The main out-
put voltage is controlled to be in regulation within 4096
clock cycles (1/fOSC). The negative and positive low-
power charge pumps are controlled to be in regulation
within 2048 clock cycles.
Power-Up Sequencing
Upon power-up or exiting shutdown, the MAX1747
starts a power-up sequence. First, the reference pow-
ers up. Then the primary charge pump powers up with
soft-start enabled. Once the main charge pump reach-
es 90% of its nominal value (VFB > 1.125V), the nega-
tive charge pump turns on. When the negative output
voltage reaches approximately 90% of its nominal value
(VFBN < 125mV), the positive charge pump starts up.
Finally, when the positive output voltage reaches 90%
of its nominal value (VFBP > 1.125V), the active-low
ready signal (RDY) goes low (see Power Ready).
Fault Detection
Once RDY is low, and if any output falls below its fault
detection threshold, RDY goes high impedance.
For the reference, the fault threshold is 1.05V. For the
main charge pump, the fault threshold is 88% of its
nominal value (VFB < 1.1V). For the negative charge
pump, the fault threshold is approximately 88% of its
nominal value (VFBN > 140mV). For the positive charge
pump, the fault threshold is 88% of its nominal value
(VFBP < 1.1V).
Once an output faults, all outputs later in the power
sequence shut down until the faulted output rises
above its power-up threshold. For example, if the nega-
tive charge-pump output voltage falls below the fault-
detection threshold, the main charge pump remains
active while the positive charge pump stops switching
and its output voltage decays, depending on output
capacitance and load. The positive charge-pump out-
put will not power up until the negative charge-pump
output voltage rises above its power-up threshold (see
Power-Up Sequencing).
Power Ready
Power ready is an open-drain output. When the power-
up sequence is properly completed, the MOSFET turns
on and pulls RDY low with a typical 125RON. If a fault
is detected, the internal open-drain MOSFET appears
as a high impedance. Connect a 100kpullup resistor
between RDY and IN for a logic level output.
Voltage Reference
The voltage at REF is nominally 1.25V. The reference
can source up to 50mA with excellent load regulation
(see Typical Operating Characteristics). Connect a
0.22µF bypass capacitor between REF and GND.
During shutdown, the reference is disabled.
Design Procedure
Efficiency Considerations
The efficiency characteristics of the MAX1747 regulat-
ed charge pumps are similar to a linear regulator. They
are dominated by quiescent current at low output cur-
rents and by the input voltage at higher output currents
(see Typical Operating Characteristics). Therefore, the
maximum efficiency may be approximated by:
Efficiency VOUT / (2 VSUPM) for the main
charge pump
Efficiency - VNEG / (VSUPN N) for the negative
low-power charge pump
______________________________________________________________________________________ 11

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]