ELECTRICAL CHARACTERISTICS — continued (TC = 25°C unless otherwise noted)
Characteristic
Symbol
Min
FUNCTIONAL TESTS (In Motorola Test Fixture, 50 ohm system)
Two–Tone Common–Source Amplifier Power Gain
(VDD = 26 Vdc, Pout = 60 W PEP, IDQ = 450 mA,
f1 = 945.0 MHz, f2 = 945.1 MHz)
Gps
17
Two–Tone Drain Efficiency
(VDD = 26 Vdc, Pout = 60 W PEP, IDQ = 450 mA,
f1 = 945.0 MHz, f2 = 945.1 MHz)
η
37
3rd Order Intermodulation Distortion
(VDD = 26 Vdc, Pout = 60 W PEP, IDQ = 450 mA,
f1 = 945.0 MHz, f2 = 945.1 MHz)
IMD
—
Input Return Loss
(VDD = 26 Vdc, Pout = 60 W PEP, IDQ = 450 mA,
f1 = 945.0 MHz, f2 = 945.1 MHz)
IRL
—
Two–Tone Common–Source Amplifier Power Gain
(VDD = 26 Vdc, Pout = 60 W PEP, IDQ = 450 mA,
f1 = 930.0 MHz, f2 = 930.1 MHz and f1 = 960.0 MHz,
f2 = 960.1 MHZ)
Gps
—
Two–Tone Drain Efficiency
(VDD = 26 Vdc, Pout = 60 W PEP, IDQ = 450 mA,
f1 = 930.0 MHz, f2 = 930.1 MHz and f1 = 960.0 MHz,
f2 = 960.1 MHZ)
η
—
3rd Order Intermodulation Distortion
(VDD = 26 Vdc, Pout = 60 W PEP, IDQ = 450 mA,
f1 = 930.0 MHz, f2 = 930.1 MHz and f1 = 960.0 MHz,
f2 = 960.1 MHZ)
IMD
—
Input Return Loss
(VDD = 26 Vdc, Pout = 60 W PEP, IDQ = 450 mA,
f1 = 930.0 MHz, f2 = 930.1 MHz and f1 = 960.0 MHz,
f2 = 960.1 MHZ)
IRL
—
Typ
18
40
–31.5
–14.5
18
40
–31
–12.5
Max
Unit
—
dB
—
%
–28
dBc
–9
dB
—
dB
—
%
—
dBc
—
dB
MOTOROLA RF DEVICE DATA
MRF9060MR1 MRF9060MBR1
3