PEB 3065
PEF 3065
IOM®-2 Interface
IOM®-2 Time Slot Assignment
An assignment of 8 time slots is possible for each voice-channel. The IOM-2 operating
mode and time slot selection is set completely by pin-strapping.
Table 7
SEL24 TS2
TS1
TS0
IOM®-2 Operating Mode
0
0
0
0
Time slot 0; DCL = 2048 kHz
0
0
0
1
Time slot 1; DCL = 2048 kHz 1)
0
0
1
0
Time slot 2; DCL = 2048 kHz 1)
0
0
1
1
Time slot 3; DCL = 2048 kHz 1)
0
1
0
0
Time slot 4; DCL = 2048 kHz
0
1
0
1
Time slot 5; DCL = 2048 kHz 1)
0
1
1
0
Time slot 6; DCL = 2048 kHz
0
1
1
1
Time slot 7; DCL = 2048 kHz
1
0
0
0
Time slot 0; DCL = 4096 kHz
1
0
0
1
Time slot 1; DCL = 4096 kHz
1
0
1
0
Time slot 2; DCL = 4096 kHz
1
0
1
1
Time slot 3; DCL = 4096 kHz
1
1
0
0
Time slot 4; DCL = 4096 kHz
1
1
0
1
Time slot 5; DCL = 4096 kHz
1
1
1
0
Time slot 6; DCL = 4096 kHz
1
1
1
1
Time slot 7; DCL = 4096 kHz
1) Time slots 1, 2, 3 and 5 are not working with DCL = 2048 kHz.
For a workaround in the 2MHz mode please contact the SIEMENS HL Application group.
Semiconductor Group
18
01.98