DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

5063JD 查看數據表(PDF) - Unspecified

零件编号
产品描述 (功能)
生产厂家
5063JD Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
BCcomponents
Metal film resistors
Product specification
5063JD series (space miser)
0.25 to 0.40 W; 1% and 5%
Definition of symbols (see Figs 4, 5, 6 and 7)
SYMBOL
Pˆ
Pˆ max
Vˆ i
Vˆ max
V(t)
R
PU
Rnom
ti
tp
DESCRIPTION
applied peak pulse power
maximum permissible peak pulse power;
see Fig.4
applied peak pulse voltage; see Fig 6
maximum permissible peak pulse voltage;
see Fig.5
pulse voltage
nominal resistance value
rated dissipation at ambient temperature
nominal resistance value
pulse duration (rectangular pulses)
pulse repetition time
Pulses
The permissible pulse-load is determined by the resistance
change as given for the endurance test after 8000 hours.
PULSE VOLTAGE LIMIT
The maximum permissible impulse voltage Vˆ max is the
voltage pulse short overload depending on the impulse time
ti. High ohmic values are protected by the interdependence
of voltage limit and impulse time. this function is given by
the equation:
Vˆ max
=
2----.-5--------V-----m----a---x
1 + ti K
+
V
m
ax
Vmax = maximum permissible continuous voltage;
ti = pulse time;
K = 100 s1.
MAXIMUM PULSE-LOAD
The average load P must not exceed the rated dissipation.
For resistance values above the critical resistance the rated
dissipation is given by the resistance value and the limiting
element
voltage
Vmax:
P
=
---1-----
tpR
tt
2
1
U2(t)dt
Pυ
PULSE SHAPES
Figure 6 shows the maximum pulse-load for a rectangular
pulse shape:
P
=
-t-i------V--ˆ--2-
tp R
Other pulses should be converted into rectangular pulse
shapes (see Fig.7), having the same energy at a given peak
voltage. The following equation shows the calculation for
exponential pulses:
P
=
----τ---e----
2 tp
-V--ˆ--2-
R
with
τe
=
RC
or
τe
=
-L--
R
V
tp
ti
Vi
MGA206
t
Fig.6 Rectangular pulses.
MGA207
V
tp
CONTINUOUS AND SINGLE PULSE-LOAD
There is a difference between repetitive pulse-load
P
=
-t--i
tp
P
with
P
=
power
at
the
pulse
time
ti
or
single pulse load (e.g. switching events P > 0 ).
A higher pulse-load Pmax is accepted in the latter case.
τ
t
Fig.7 Exponential pulses.
2000 Aug 08