Insulation and Safety Related Specifications
Parameter
Symbol
Minimum External Air
Gap (Clearance)
L(I01)
Minimum External
Tracking (Creepage)
L(I02)
Minimum Internal Plastic
Gap (Internal Clearance)
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
Value
≥5
≥5
0.08
≥175
IIIa
Units
mm
mm
mm
Volts
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Insulation thickness between emitter and detector;
also known as distance through insulation.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
All Avago Technologies data sheets report the creepage
and clearance inherent to the optocoupler component it-
self. These dimensions are needed as a starting point for
the equipment designer when determining the circuit
insulation requirements. However, once mounted on a
printed circuit board, minimum creepage and clearance
requirements must be met as specified for individual
equipment standards. For creepage, the shortest distance
path along the surface of a printed circuit board between
the solder fillets of the input and output leads must be
considered. There are recommended techniques such as
grooves and ribs which may be used on a printed circuit
board to achieve desired creepage and clearances. Creep-
age and clearance distances will also change depending
on factors such as pollution degree and insulation level.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option 060)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤150 V rms
for rated mains voltage ≤300 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b†
VIORM x 1.875 = VPR, 100% Production
Test with tm = 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a†
VIORM x 1.5 = VPR, Type and Sample Test,
tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage†
(Transient Overvoltage, tini = 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 11.)
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, V10 = 500 V
Symbol
VIORM
VPR
VPR
VIOTM
Ts
Is, INPUT
Ps,OUTPUT
RIO
option 060
I-IV
I-III
55/105/21
2
560
1050
840
4000
150
150
600
≥109
Units
VPEAK
VPEAK
VPEAK
VPEAK
°C
mA
mW
Ω
5