ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 2.
Parameter
VCC
RESET
Output Current (RESET)
Operating Temperature Range
Storage Temperature Range
θJA Thermal Impedance, SC70
Soldering Temperature
Sn/Pb
Pb-Free
Rating
−0.3 V to +6 V
−0.3 V to +6 V
20 mA
−40°C to +125°C
−65°C to +150°C
331°C/W
240°C, 30 sec
260°C, 40 sec
ADM6384
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
Rev. C | Page 5 of 12