DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ADUM2200ARWZ 查看數據表(PDF) - Analog Devices

零件编号
产品描述 (功能)
生产厂家
ADUM2200ARWZ Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ADuM2200/ADuM2201
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)1
Input Capacitance2
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
Symbol
RI-O
CI-O
CI
θJCI
θJCO
Min Typ Max Unit Test Conditions
1012
Ω
2.2
pF
f = 1 MHz
4.0
pF
33
°C/W Thermocouple located at
28
°C/W center of package underside
1 Device considered a 2-terminal device: Pin 1 through Pin 8 are shorted together and Pin 9 through Pin 16 are shorted together.
2 Input capacitance is from any input data pin to ground.
REGULATORY INFORMATION
The ADuM220x are approved by the organizations listed in Table 5. Refer to Table 10 and the Insulation Lifetime section for details
regarding recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 5.
UL (Pending)
Recognized under the UL 1577
component recognition program1
Double/reinforced insulation,
5000 V rms isolation voltage
File E214100
CSA (Pending)
Approved under CSA Component
Acceptance Notice #5A
Reinforced insulation per CSA 60950-1-03
and IEC 60950-1, 600 V rms (848 V peak)
maximum working voltage
Reinforced insulation per IEC 60601-1
250 V rms (353 V peak) maximum working
voltage
File 205078
VDE (Pending)
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-122
Reinforced insulation, 846 V peak
File 2471900-4880-0001
1 In accordance with UL 1577, each ADuM220x is proof-tested by applying an insulation test voltage ≥ 6000 V rms for 1 second (current leakage detection limit = 10 μA).
2 In accordance with DIN V VDE V 0884-10, each ADuM220x is proof-tested by applying an insulation test voltage ≥1590 V peak for 1 second (partial discharge detection
limit = 5 pC). The asterisk (*) branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Symbol
L(I01)
L(I02)
CTI
Value
5000
7.46 min
8.10 min
0.017 min
>175
IIIa
Unit
V rms
mm
mm
mm
V
Conditions
1-minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Rev. 0 | Page 10 of 20