AUTOMATIC PROGRAMMING TIMING WAVEFORM
One byte data is programmed. Verify in fast algorithm
and additional programming by external control are not
required because these operations are excuted auto-
matically by internal control circuit. Programming
completion can be verified by status register after
automatic Program starts.
AUTOMATIC PROGRAMMING TIMING WAVEFORM-BYTE MODE
MX28F2100B
Vcc 5V
12V
Vpp
0V
RP
BYTE VIH
VIL
VIH
ADD
A-1~16 VIL
CE VIH
VIL
WE VIH
VIL
OE VIH
VIL
DATA VIH
Q0~Q2 VIL
VIH
DATA
Q3~Q7 VIL
VIH
DATA
Q8~Q14 VIL
tVPS
tPHEL
tAS
tCWC
tCS
tCH tCS
ADD Valid
tCH
tCESP
tCEPH1
tOES tCEP
tCEP
tCES
tDS
tDH tDS
Command In
tDH
DIN
10H/or 40H
Command In
DIN
High Z
tVPH
tCESC
tDF
Valid SRD
P/N: PM0382
REV. 1.5, MAR. 24, 1998