ATtiny13
Clock Sources
Default Clock Source
The device has the following clock source options, selectable by Flash Fuse bits as
shown below. The clock from the selected source is input to the AVR clock generator,
and routed to the appropriate modules.
Table 2. Device Clocking Options Select(1)
Device Clocking Option
CKSEL1..0
Calibrated Internal RC Oscillator
01, 10
External Clock
00
128 kHz Internal Oscillator
11
Note: 1. For all fuses “1” means unprogrammed while “0” means programmed.
The various choices for each clocking option is given in the following sections. When the
CPU wakes up from Power-down or Power-save, the selected clock source is used to
time the start-up, ensuring stable Oscillator operation before instruction execution starts.
When the CPU starts from reset, there is an additional delay allowing the power to reach
a stable level before commencing normal operation. The Watchdog Oscillator is used
for timing this real-time part of the start-up time. The number of WDT Oscillator cycles
used for each time-out is shown in Table 3.
Table 3. Number of Watchdog Oscillator Cycles
Typ Time-out
4 ms
64 ms
Number of Cycles
512
8K (8,192)
The device is shipped with CKSEL = “10”, SUT = “10”, and CKDIV8 programmed. The
default clock source setting is therefore the Internal RC Oscillator running at 9.6 MHz
with longest start-up time and an initial system clock prescaling of 8. This default setting
ensures that all users can make their desired clock source setting using an In-System or
High-voltage Programmer.
21