DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

E6F-AG5C-C7202M 查看數據表(PDF) - OMRON Corporation

零件编号
产品描述 (功能)
生产厂家
E6F-AG5C-C7202M
Omron
OMRON Corporation Omron
E6F-AG5C-C7202M Datasheet PDF : 32 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Operating Procedures
Flow of Operation
Initial Settings
Setting Resolution and
Rotation Direction
The Encoder resolution and rotation direction is set on a DIP switch.
For details on the setting methods, refer to page 21.
Setting the Origin
The Encoder is mounted to the machine and the origin for operation is determined.
For details on the setting methods, refer to page 21.
Setting Functions
Advanced Parameters can be set in Function Setting Mode to perform more advanced operations.
function For details, refer to page 26 Advanced Functions.
H8PS
Programming Cams (Programming Mode)
Setting ON/OFF Angles
Setting the ADV Function
There are three methods that can be used to set or change ON/OFF angles (i.e., cam programming).
Using the ANGLE Keys (Manual Mode)
Actually turning the Encoder (Teaching Mode)
Setting from personal computer using Support Software (order separately)
For details on the setting methods, refer to pages 22 to 23.
Advanced Advance angle compensation (ADV) function can be set if required.
function For details on the setting methods, refer to page 27.
Checking Timing (Test Mode)
The machine is operated and outputs are actually made to check the timing of operation.
If the timing of operation is not correct, it can be changed.
For details, refer to page 23.
Operation (Run Mode)
Operation is started.
For details, refer to page 24.
The ON/OFF angles that have been set can be checked.
Checking ON/OFF Angle Settings For details, refer to page 24.
Clearing Settings
Deletes settings. There are two methods that can be used to delete settings.
Clearing all programs (deletes all programming)
Clearing individual steps, cams, and banks
For details, refer to page 25.
Settings for Basic Functions
Changing the Mode
PRG
TST
RUN
PRG
TST
RUN
PRG
TST
RUN
Programming Mode PRG
Changed with the mode switch.
Test Mode
TST
Changed with the mode switch.
Run Mode
RUN
ADV Key
5 s min.
ON/OFF Key
1 s min.
Programming Mode
Used to write cam programs, set the advance angle compensation
function, etc.
All outputs will remain OFF.
Test Mode
Used to write cam programs, set the advance angle compensation
function, and perform other operations while actually turning ON
outputs to confirm operation timing. This mode is also used to adjust
settings during operation.
Run Mode
Used for normal operation. Settings, such as writing cam programs
and setting the advance angle compensation function, cannot be
performed.
All Protection
Disables all keys
and switches.
will light when the all
protection function is
enabled.
Refer to page 24.
Switching the Angle
and Speed Display
Main Display: Angle
Sub-display: Speed
↓↑
Main Display: Speed
Sub-display: Angle
Refer to page 24.
20

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]