1 2 3 4 5 6 7 8 9 10 Next Last
All Avago data sheets report the creepage and clearance
inherent to the optocoupler component itself. These
dimensions are needed as a starting point for the
equipment designer when determining the circuit insula-
tion requirements. However, once mounted on a printed
circuit board, minimum creepage and clearance require-
ments must be met as specified for individual equipment
standards. For creepage, the shortest distance path along
the surface of a printed circuit board between the solder
fillets of the input and output leads must be considered.
There are recommended techniques such as grooves
and ribs, which may be used on a printed circuit board
to achieve desired creepage and clearances. Creepage
and clearance distances will also change depending
on factors such as pollution degree and insulation
level.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics (Option 060)
Characteristic
Description
Symbol HCPL-7723 HCPL-0723 Unit
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage 150 Vrms
for rated mains voltage 300 Vrms
for rated mains voltage 600 Vrms
Climatic Classification
I – IV
I – III
I – IV
55/85/21
I – IV
I – III
I – III
55/85/21
Pollution Degree (DIN VDE 0110/39)
2
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM
630
567
Vpeak
VIORM x 1.875 = VPR, 100% Production Test with tm=1 sec,
Partial discharge < 5 pC
VPR
1181
1063
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC
Highest Allowable Overvoltage (Transient Overvoltage tini = 60 sec)
Safety-limiting values – maximum values allowed in the event of a failure
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
VPR
VIOTM
1008
8000
TS
IS, INPUT
PS, OUTPUT
RS
175
230
600
109
907
6000
150
150
600
109
Vpeak
Vpeak
°C
mA
mW
*Refer to the optocoupler section of the Isolation and Control Component Designer’s Catalog, under Product Safety Regulations section IEC/EN/
DIN EN 60747-5-5, for a detailed description of Method a and Method b partial discharge test profiles.
6