HM62W16258BI Series
DC Characteristics
Parameter
Symbol Min Typ*1 Max Unit Test conditions
Input leakage current
|ILI|
—
—
1
µA Vin = VSS to VCC
Output leakage current
|ILO|
—
—
1
µA CS = VIH or OE = VIH or WE = VIL, or
LB = UB =VIH,, VI/O = VSS to VCC
Operating current
I CC
—
—
20
mA CS = VIL, Others = VIH/VIL, II/O = 0 mA
Average HM62W16258BI-7 ICC1
—
operating
current
—
70
mA Min. cycle, duty = 100%,
II/O = 0 mA, CS = VIL,
Others = VIH/VIL
I CC2
—
3
15
mA Cycle time = 1 µs, duty = 100%,
II/O = 0 mA, CS ≤ 0.2 V,
VIH ≥ VCC – 0.2 V, VIL ≤ 0.2 V
Standby current
I SB
—
—
0.3
mA CS = VIH
Standby current
I SB1
—
1
40
µA 0 V ≤ Vin
CS ≥ VCC – 0.2 V
Output high voltage
VOH
2.4
—
—
V
IOH = –1 mA
VCC – 0.2 —
—
V
IOH = –100 µA
Output low voltage
VOL
—
—
0.4
V
IOL = 2 mA
—
—
0.2
V
IOL = 100 µA
Notes: 1. Typical values are at VCC = 3.0 V, Ta = +25°C and not guaranteed.
Capacitance (Ta = +25°C, f = 1.0 MHz)
Parameter
Symbol Min
Typ
Max
Input capacitance
Cin
—
—
8
Input/output capacitance CI/O
—
—
10
Note: 1. This parameter is sampled and not 100% tested.
Unit
pF
pF
Test conditions Note
Vin = 0 V
1
VI/O = 0 V
1
5