LA1650, 1650C
The following three techniques are practical test procedures. Note that since the output from the LA1650 pin 16 is
inverted from the value of the time code, an inverter must be inserted between the output and the microcontroller.
• Continuously output a signal with the value 1 (fc = 40 kHz, AM modulation (90%), fm = 1 Hz (square wave, duty =
50%)) and read out the value 1 from the LA1650. Then, lower the signal generator level until the LA1650 can no
longer correctly output the 1 level. The minimum signal generator level at which correct reception occurs is the
sensitivity.
When monitoring the LA1650 output signal with a microcontroller, monitor the output pulse width for the range listed
in table 1. The output signal should be observed to be a 1 Hz signal, with a period of 1000 ±25 ms. (See figure 3.)
Table 1 Signal Value 1 Range
Item
Output pulse width
(500 ms input)
min typ max unit
480 500 650 ms
TCO rise (reference)
1000 ±25 ms
480 to 650 ms
A12777
Figure 3 Time Code Value 1 Signal Output
• Continuously output a signal with the value 0 (fc = 40 kHz, AM modulation (90%), fm = 1 Hz (square wave, duty =
80%)) and read out the value 0 from the LA1650. Then, lower the signal generator level until the LA1650 can no
longer correctly output the 0 level. The minimum signal generator level at which correct reception occurs is the
sensitivity.
When monitoring the LA1650 output signal with a microcontroller, monitor the output pulse width for the range listed
in table 2. The output signal should be observed to be a 1 Hz signal, with a period of 1000 ±25 ms. (See figure 4.)
Table 2 Signal Value 0 Range
Item
Output pulse width
(800 ms input)
min typ max unit
750 800 970 ms
TCO rise (reference)
1000 ±25 ms
750 to 970 ms
A12778
Figure 4 Time Code Value 0 Signal Output
• Create a simulated time standard radio signal (fc = 40 kHz, AM modulation (90%), fm = 1 Hz time code (this signal
you will have to create yourself)) and verify that the time is modified correctly. The sensitivity is then the minimum
level for which the time is modified correctly.
When monitoring the LA1650 output signal with a microcontroller, monitor the output pulse width for the ranges listed
in table 3. The output signal should be observed to be a 1 Hz signal, with a period of 1000 ±25 ms. (See figure 4.)
Table 3 Time Code Signal Output Ranges
Item
Output pulse width
(500 ms input)
Output pulse width
(800 ms input)
Output pulse width
(200 ms input)
min typ max unit
480 500 650 ms
750 800 970 ms
180 200 400 ms