First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
M41T62/63/64/65
Setting Alarm Clock Registers
Address locations 0Ah-0Eh contain the alarm set-
tings. The alarm can be configured to go off at a
prescribed time on a specific month, date, hour,
minute, or second, or repeat every year, month,
day, hour, minute, or second. Bits RPT5–RPT1
put the alarm in the repeat mode of operation. Ta-
ble 7., page 19 shows the possible configurations.
Codes not listed in the table default to the once per
second mode to quickly alert the user of an incor-
rect alarm setting.
When the clock information matches the alarm
clock settings based on the match criteria defined
by RPT5–RPT1, the AF (Alarm Flag) is set. If AFE
(Alarm Flag Enable) is also set (M41T62/65), the
alarm condition activates the IRQ/OUT or IRQ/FT/
OUT pin. To disable the alarm, write '0' to the
Alarm Date Register and to RPT5–RPT1.
Note: If the address pointer is allowed to incre-
ment to the Flag Register address, an alarm con-
dition will not cause the Interrupt/Flag to occur until
the address pointer is moved to a different ad-
dress. It should also be noted that if the last ad-
dress written is the “Alarm Seconds,” the address
pointer will increment to the Flag address, causing
this situation to occur.
The IRQ output is cleared by a READ to the Flags
Register as shown in Figure 22., page 19. A sub-
sequent READ of the Flags Register is necessary
to see that the value of the Alarm Flag has been
reset to '0.'
Figure 22. Alarm Interrupt Reset Waveform
0Eh
0Fh
00h
ALARM FLAG BIT (AF)
IRQ/OUT or
IRQ/FT/OUT
Table 7. Alarm Repeat Modes
RPT5
RPT4
RPT3
1
1
1
1
1
1
1
1
1
1
1
0
1
0
0
0
0
0
RPT2
1
1
0
0
0
0
RPT1
1
0
0
0
0
0
HIGH-Z
AI08898
Alarm Setting
Once per Second
Once per Minute
Once per Hour
Once per Day
Once per Month
Once per Year