M48T58, M48T58Y
8
DC and AC parameters
DC and AC parameters
Note:
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC Characteristic
tables are derived from tests performed under the Measurement Conditions listed in Table 7.
Designers should check that the operating conditions in their projects match the
measurement conditions when using the quoted parameters.
Table 7. Operating and AC measurement conditions
Parameter
M48T58
M48T58Y
Unit
Supply Voltage (VCC)
4.75 to 5.5
4.5 to 5.5
V
Ambient Operating Temperature (TA)
0 to 70
0 to 70
°C
Load Capacitance (CL)
100
100
pF
Input Rise and Fall Times
≤5
≤5
ns
Input Pulse Voltages
0 to 3
0 to 3
V
Input and Output Timing Ref. Voltages
1.5
1.5
V
Output Hi-Z is defined as the point where data is no longer driven.
Figure 11. AC measurement load circuit
5V
DEVICE
UNDER
TEST
1kΩ
1.9kΩ
OUT
CL = 100pF or 5pF
CL includes JIG capacitance
AI01030
Table 8. Capacitance
Symbol
Parameter(1)(2)
Min
Max
CIN
Input Capacitance
10
COUT(3)
Output Capacitance
10
1. Effective capacitance measured with power supply at 5V; sampled only, not 100% tested.
2. At 25°C, f = 1MHz.
3. Outputs deselected.
Unit
pF
pF