DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX3463 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
生产厂家
MAX3463 Datasheet PDF : 14 Pages
First Prev 11 12 13 14
+5V, Fail-Safe, 20Mbps, Profibus RS-485/
RS-422 Transceivers
B
ATE
VID
R
RECEIVER
OUTPUT
A
Figure 12. Receiver Propagation Delay Test Circuit
Applications Information
128 Transceivers on the Bus
The standard RS-485 receiver input impedance is 12k
(one-unit load), and the standard driver can drive up to
32 unit loads. The MAX3460MAX3464 family of trans-
ceivers has a 1/4-unit-load receiver input impedance
(48k), allowing up to 128 transceivers to be connect-
ed in parallel on one communication line. Any combina-
tion of these devices and/or other RS-485 transceivers
with a total of 32 unit loads or less can be connected to
the line.
Low-Power Shutdown Mode
(except MAX3462)
Low-power shutdown mode is initiated by bringing
SHDN high (MAX3460/MAX3461), or both RE high and
DE low. In shutdown, the devices typically draw only
1µA of supply current. RE and DE can be driven simul-
taneously; the parts are guaranteed not to enter shut-
down if RE is high and DE is low for less than 50ns. If
the inputs are in this state for at least 800ns, the parts
are guaranteed to enter shutdown.
Driver Output Protection
Two mechanisms prevent excessive output current and
power dissipation caused by faults or by bus con-
tention. The first, a foldback current limit on the output
stage, provides immediate protection against short cir-
cuits over the whole common-mode voltage range (see
Typical Operating Characteristics). The second, a ther-
mal shutdown circuit, forces the driver outputs into a
high-impedance state if the die temperature exceeds
+140°C.
Propagation Delay
Many digital encoding schemes depend on the difference
between the driver and receiver propagation delay times.
Typical propagation delays are shown in the Typical
Operating Characteristics. The difference in receiver delay
times, |tPLH - tPHL|, is a maximum of 2ns. The driver skew
time |tPLH - tPHL| is also a maximum of 2ns.
Typical Applications
The MAX3460MAX3464 transceivers are designed for
bidirectional data communications on multipoint bus
transmission lines. Figures 13 and 14 show typical net-
work applications circuits. To minimize reflections, the
line should be terminated at both ends in its character-
istic impedance, and stub lengths off the main line
should be kept as short as possible.
Profibus Termination
The MAX3460MAX3464 are designed for driving
Profibus termination networks. With a worst-case load-
ing of two termination networks with 220termination
impedance and 390pullups and pulldowns, the dri-
vers can drive VA-B> 2.1V output.
Chip Information
TRANSISTOR COUNT: 610
PROCESS: BiCMOS
Ordering Information (continued)
PART
MAX3461CSD
MAX3461CPD
MAX3461ESD
MAX3461EPD
MAX3462CSA
MAX3462CPA
MAX3462ESA
MAX3462EPA
MAX3463CSA
MAX3463CPA
MAX3463ESA
MAX3463EPA
MAX3464CSA
MAX3464CPA
MAX3464ESA
MAX3464EPA
TEMP RANGE
0°C to +70°C
0°C to +70°C
-40°C to +85°C
-40°C to +85°C
0°C to +70°C
0°C to +70°C
-40°C to +85°C
-40°C to +85°C
0°C to +70°C
0°C to +70°C
-40°C to +85°C
-40°C to +85°C
0°C to +70°C
0°C to +70°C
-40°C to +85°C
-40°C to +85°C
PIN-PACKAGE
14 SO
14 Plastic DIP
14 SO
14 Plastic DIP
8 SO
8 Plastic DIP
8 SO
8 Plastic DIP
8 SO
8 Plastic DIP
8 SO
8 Plastic DIP
8 SO
8 Plastic DIP
8 SO
8 Plastic DIP
______________________________________________________________________________________ 11