622Mbps LAN/WAN Laser Driver with
Automatic Power Control and Safety Shutdown
SAFETY
CSAFETY
FAILURE
(INTERNAL)
VCC
200k
OPEN
COLLECTOR
ENABLE
100k
OPEN
COLLECTOR
FAIL
S
RESET DOMINATE
RS FLIP-FLOP
Q
SIMPLIFIED
OPEN-COLLECTOR
OUTPUT CIRCUIT OUT
R
SHDN
IN
(INTERNAL)
Figure 4. Simplified Safety Circuit Schematic
Latched Shutdown Configuration
This configuration is shown in the Typical Application
Circuits (configured for best performance), and can
be selected by connecting a capacitor (CSAFETY) to
ground at SAFETY. In this configuration, the transmitter
is shut down when a failure is detected. It can be
restarted only by a power-on cycle or a toggle of the
ENABLE input.
During start-up, FAIL is asserted until laser power reach-
es the programmed level. The safety circuit must be dis-
abled at power-on or at transmitter enable, providing
enough time for the APC circuit to reach the programmed
laser power level.
In space-constrained designs, CSAFETY can be select-
ed to provide a shutdown delay. When power is initially
applied, or when the ENABLE signal is toggled from a
logic 0 to a logic 1, the voltage at SAFETY is low, and
rises with a time constant set by CSAFETY and an inter-
nal 200kpull-up resistor. The SAFETY signal is invert-
ed and resets the input of a reset-dominant RS flip-flop.
The internal signal FAILURE from the failure-detection
circuit is connected to the set input of the flip-flop. After
SAFETY has gone high (allowing time for the APC feed-
back loop to settle) and if internal signal FAILURE is low,
the flip-flop output is low, and the bias and modulation
outputs are allowed to remain on. Refer to Figure 5 for
a timing diagram of start-up in the latched shutdown
configuration.
VCC
VCC ON (OR ENABLE SWITCHED TO ON STATE)
tON
LASER BIAS AND
MODULATION CURRENT
OUTPUT CURRENTS ENABLED AFTER A FIXED DELAY
FAIL
OUTPUT
tAPC
FAIL DEASSERTS WHEN THE APC LOOP SETTLES
SAFETY
tSAFETY
SAFETY FEATURES START CHECKING
THE FAILURE SIGNAL AFTER A TIME SET
BY A CAPACITOR ON THE SAFETY INPUT.
AFTER THIS TIME, THE LASER DRIVER IS
DISABLED IF A FAILURE OCCURS.
Figure 5. Start-Up Sequence Timing
The duration of tSAFETY must be about 10 times tAPC for
a successful start-up. After start-up, the transmitter
operates normally until a failure is detected, causing
the output currents to be shut down. The laser-current
outputs remain off until the failure condition is eliminat-
ed and the ENABLE input is toggled, or until the power
is cycled. A potential problem with this transmitter-
enable method is that a slow-rising power supply may
not enable the transmitter.
10 ______________________________________________________________________________________