Functional Overview MT312
AGC control
RF I/P
I
Direct
Conversion
ZIF Tuner
Q
SL1935
Tank
Low pass
Filter
I I/P
Q I/P
Channel
Decoder
MT312
Transport
stream O/P
2-wire bus
control
2-wire bus control
Figure 13 - Alternative System Block Diagram - SNIM6
1.7 DiSEqC™ Transmit and Receive Messages
The MT312 has the capability to send and receive
DiSEqCmessages. Eight registers are provided to
store a message for transmission and a further eight
registers are provided to store a received message.
The received bytes have a parity bit and a parity
error bit in addition to the eight data bits. These
additional bits are read out in following the data bits,
so two byte reads are required for each data byte.
1.7.1 DiSEqC™ Transmitting Messages
The sequence of events to send a message are as
follows:
1. Load the required message bytes into the
DiSEqCInstruction register 36, see page 34.
Sequential writes to the same register is achieved
by setting the Inhibit Auto Incrementing (IAI) bit 7
in RADD, the register address byte.
2. Load the number of bytes (less one) in the
DiSEqCinstruction in the register
DISEQC MODE[5:3], see page 32.
3. Set DISEQC MODE[2:0] = 4 to command the
MT312 to encode the data and transmit the
message.
4. Reset DISEQC MODE[2:0] to either 0 or 1
depending on previous setting of 22kHz off or on.
transmitted. If a return message is expected, the
DISEQC MODE[2:0] must be set to zero in order to
leave the LNB control signal free for another
DiSEqCtransmitter to respond.
The sequence of events to receive a message are as
follows:
1. Enable DiSEqC2 GPP2 pin 46 as an input by
setting GPP CTRL register 20 B5 to zero.
2. Enable interrupts if the IRQ pin is being used to
interrupt the host processor in DISEQC2 CTRL1
register 121.
3. Monitor DISEQC2 INT register.
4. If B3 = 1 and B1 = 0, there has been no message
received.
5. If a message has been received, B0 will be set, If
B1 is also set the message is complete.
DISEQC2 INT register B7-4 indicate how many
bytes have been received.
6. Read the received message from
DISEQC2 FIFO register 120 by setting the Inhibit
Auto Incrementing (IAI) bit 7 in RADD, the register
address byte and sequentially reading
DISEQC2 FIFO for the indicated number of
bytes. Each data byte read requires two 2-wire
bus reads. The second or the pair of bytes
contains the parity bit and a parity bit error
indicator.
The data loaded into DISEQC INSTR register is
retained, so that if the same message is to be
repeated, the data loading stage 1 above can be
omitted.
1.7.2 DiSEqC™ Receiving Messages
The MT312 will automatically listen for DiSEqC
messages 5ms after a message has been
The user may choose to wait for the end of message
indication, before reading the message, if it is known
that the message is not greater than eight bytes.
However, if the length of message is not known, the
message should be read out of the FIFO by the host
as it is being received. Care must be taken to avoid a
FIFO buffer overow. DISEQC2 INT register B7-4 will
indicate how many bytes remain in the FIFO.
17