Philips Semiconductors
48 × 84 dot matrix LCD driver
Product specification
OM6211
Table 4 Typical values for parameters of the HV generator programming
SYMBOL
TC0
TC1
TC2
a
4.57
4.28
4.04
b
30.0
28.0
26.5
Tnom
TC
27
27
27
0
−0.25
−0.5
TC3
3.79
25.0
27
−0.75
UNIT
V
mV
°C
10-3/°C
Example: to achieve VLCD = 8.3 V at temperature Tnom for TC3 it is necessary to set VPR = 180 (decimal).
Example for calibration: Before calibration VPR = 180 was applied, but the measured voltage was VLCD = 8.4 V.
To decrease VLCD by 100 mV the best value for VOS is −4 decimal (11100 binary in the two’s complement notation). So
after calibration with VOS = −4 the proper VPR value is still 180.
As VOS is used for calibration and the default value is 0, for selecting the value of VPR it can always be considered that
VOS = 0.
handbook, full pagewidth
V LCD
MGT847
b
a
00 01 02 03 04 05 06 . . .
VOP7 to VOP0 programming, (00H to FFH).
Fig.5 VLCD programming of OM6211.
. . . FD FE FF
V OP
2002 Jan 17