Philips Semiconductors
FLEXPager Decoder
Product specification
PCD5008
7 PINNING
SYMBOL PIN
TOUT0
1
OSCPD
2
VDD1
3
TEST2
4
XTAL
5
EXTAL
6
VSS1
7
TEST3
8
TOUT3
9
LOBAT
10
EXTS1
11
EXTS0
12
VDD2
13
SYMCLK
14
S7
15
S6
16
TOUT2
17
S5
18
S4
19
S3
20
S2
21
S1
22
S0
23
RESET
24
TOUT1
25
READY
26
SS
27
SCK
28
VSS2
29
MOSI
30
MISO
31
CLKOUT
32
PAD
I/O COORDINATE
X/Y; note 1
DESCRIPTION
O
1405/1088 3-state test output; note 2
I
1405/816 internal oscillator power-down; connected to VSS when using the
internal oscillator, connected to VDD when using an external source
1405/563 supply voltage
I
1405/306 manufacturing test mode input pin; has to be connected to VSS
O
1405/76 76.8 kHz crystal oscillator output
I
1405/404 76.8 kHz crystal oscillator input or external clock input
1405/648 ground supply
I
1405/1104 manufacturing test mode input pin; has to be connected to VSS
O 1125/1400 3-state test output; note 2
I
863/1400 low battery voltage detect input
I
633/1400 most significant bit (MSB) of the symbol currently being decoded
I
398/1400 least significant bit (LSB) of the symbol currently being decoded
134/1400 supply voltage
O
569/1400 recovered symbol clock output
O
829/1400 receiver control output port, 3-state
O
1084/1400 receiver control output port, 3-state
O
1405/1093 3-state test output; note 2
O
1405/718 receiver control output port, 3-state
O
1405/398 receiver control output port, 3-state
O
1405/93 receiver control output port, 3-state
O
1405/202 receiver control output port, 3-state
O
1405/502 receiver control output port, 3-state
O
1405/812 receiver control output port, 3-state
I
1405/1114 active LOW reset input
O
1051/1400 3-state test output; note 2
O
721/1400 output driven LOW when the PCD5008 is ready for an SPI packet
I
404/1400 slave select input for SPI communications
I
149/1400 serial clock input for SPI communications
100/1400 ground supply
I
516/1400 data input for SPI communications
O
789/1400 data output for SPI communications, 3-state
O
1084/1400 38.4 kHz clock output (derived from 76.8 kHz oscillator)
Notes
1. The pad coordinates are given in µm relating to the centre of the chip and are used in case of naked die delivery.
2. These test outputs may be either left unconnected or connected to VSS in the application.