KA3050
2. Af Motor And Ae Meter Drive Block (Stepping Motor Drive Block)
MC1~MC4
VSI
Stepping Motor
Control Block
SC1~SC4
SM1
18
SM2
17
SM3
16
SM4 SM5
15
14
The block diagram describes the driver of AF motor and AE meter in camera systems.
The drive output is selected by MC signals (MC1~4).
These MC codes are as follows.
MC1
H
INPUT
MC2
MC3
L
L
L
H
L
H
H
L
H
L
H
H
H
H
MC4
H
L
H
L
H
L
H
SM1
-
-
-
L
L
H
H
SM2
-
-
-
H
H
L
L
OUTPUT
SM3
-
-
-
L
H
L
H
The output voltage (VCOIL) is determined by SC1~4.
The VCOIL is potential difference between drive output and ground.
i.e.,
VCOIL = VSM - GND.
The VCOIL is selected by following table.
SM4
L
H
L
H
L
H
L
SM5
H
L
L
-
-
-
-
12