TK116xxU
TK11650U ELECTRICAL CHARACTERISTICS
Test Conditions: TA = 25°C, VIN = 6.0 V, unless otherwise specified.
SYMBOL
PARAMETER
TEST CONDITIONS
IQ
VOUT
VDROP
IOUT
IOR
IGND
Line Reg
Load Reg
RR
Quiescent Current
Output Voltage
Dropout Voltage
Output Current
Recommended Output Current
Ground Current (Note 2)
Line Regulation
Load Regulation
Ripple Rejection
VIN = 6.0 V, IOUT = 0 mA
VIN = 4.0 V, IOUT = 0 mA
VIN = 6.0 V, IOUT = 10 mA
IOUT = 30 mA
IOUT = 100 mA
VIN = 6.0 V, (Note 1)
VIN = 6.0 V
VIN = 6.0 V, IOUT = 60 mA
VIN = 6.0 to 11.0 V
VIN = 6.0 V, IOUT = 0 to 30 mA
VIN = 6.0 V, IOUT = 0 to 100 mA
VIN = 6.0 V, IOUT = 0 to 150 mA
VIN = 6.5 V, IOUT = 10 mA,
f = 400 Hz, 100 mVrms
∆VOUT /∆T Temperature Coefficient
VIN = 6.5 V, IOUT = 10 mA,
-30
°
C
≤
T
A
≤
+80
°
C
Note 1: IOUT (Load Current) is current when VOUT drops down 0.4 V from VOUT at IOUT = 10 mA.
Note 2: Refer to “Definition of Terms.”
MIN TYP MAX UNITS
400 800
µA
0.8
2.0
mA
4.85 5.00 5.15
V
80
150 mA
170
330
mV
190
mA
150 mA
2.0
4.5
mA
2.0
30
mV
15
60
mV
40
140 mV
120
220
mV
55
dB
±0.35
mV/° C
Page 4