µPD17006AGF-011
Key
SEEK/MAN UP
SEEK/MAN DOWN
Functional Description
Hour digit adjustment
Each time SEEK/MAN DOWN key is pressed, hour advances by 1 hour. If key is held down for more than
0.5 second, hour is incremented in fast-forward mode by 1 hour every 200 ms, until key is released.
Minute digits and second count value are not affected.
Minute digit adjustment
Each time SEEK/MAN UP key is pressed, minute advances by 1 minute. If key is held down for more
than 0.5 second, minute is incremented in fast-forward mode by 1 minute every 100 ms, until key
is released.
No carry to hour digit occurs.
Each time adjustment is made, second counter is reset.
During adjustment, colon remains lighted.
When MESEL switch of initial setting diode = 1 (shorted with diode), this key is used to enable preset
memory to be written.
When data is written to preset memory, beep sound is issued for about 40 ms.
This key is invalid when MESEL switch = 0 (open).
q During frequency display
This key is used to enable preset memory to be written.
When this key is pressed, data can be written to preset memory for about 5 seconds from point
at which key is pressed. By pressing any of the
M1
to
M5
keys, currently re-
ceived frequency is written to preset memory corresponding to pressed key. If
ME
key
is held down at this time, frequency cannot be written.
In memory write-enable status, operation of each key is as follows:
ME
Key
Operation
Cancel memory write-enable status.
M1
When any of these keys is pressed, currently received frequency is written to
preset memory corresponding to pressed key. Mute output is not performed.
M5
For details, refer to description of the
M1
to
M5
keys.
PSCAN/ASM
Cancel memory write-enable status.
If this key is held down for about 2 seconds, auto store memory operation is
performed. If it is pressed less than 2 seconds, preset memory scan operation
is performed.
SEEK/MAN UP
SEEK/MAN DOWN
ME
Cancel memory write-enable status.
Operation of pressed key is started from current frequency.
Cancels memory write-enable status.