MOSEL VITELIC
V436616Y24V
Symbol Parameter
II(L)
Input Leakage Current, any input
(0 V < VIN < 3.6 V, all other inputs = 0V)
IO(L)
Output leakage current
(DQ is disabled, 0V < VOUT < VCC)
Limit Values
Min.
Max.
–40
40
–40
40
Unit
µA
µA
Capacitance
TA = 0°C to 70°C; VDD = 3.3V ± 0.3V, f = 1 MHz
Symbol Parameter
CI1
CI2
CICL
CI3
CI4
CSC
CIO
Input Capacitance (A0 to A11, RAS, CAS, WE)
Input Capacitance (CS0, CSI)
Input Capacitance (CLK0-CLK1)
Input Capacitance (CKE0, CKEI)
Input Capacitance (DQMB0-DQMB7)
Input Capacitance (SCL, SA0-2)
Input/Output Capacitance
Absolute Maximum Ratings
Parameter
Voltage on VDD Supply Relative to VSS
Voltage on Input Relative to VSS
Operating Temperature
Storage Temperature
Power Dissipation
Limit Values (Max.)
65
32
38
65
13
8
10
Unit
pF
pF
pF
pF
pF
pF
pF
Max.
-1 to 4.6
-1 to 4.6
0 to +70
-55 to 125
4
Units
V
V
°C
°C
W
Standby and Refresh Currents1
TA = 0°C to 70°C, VCC = 3.3V ± 0.3V
Symbol Parameter
Test Conditions
-75PC/75 -10PC
ICC1
Operating Current
Burst length = 4, CL = 3
tRC> = tRC(min),
tCK> = tCK(min), IO = 0 mA
2 Bank Interleave Operation
920
840
ICC2P
Precharged Standby Current in Power CKE< = VIL(max), tCK> = tCK(min)
Down Mode
8
8
ICC2N Precharged Standby Current in
CKE> = VIH(min), tCK> = tCK(min), Input 160
140
Non-Power Down Mode
changed once in 3 cycles
Unit
mA
Note
1,2
mA
mA CS = High
ICC3P
Active Standby Current in Power
Down Mode
CKE< = VIL(max), tCK> = tCK(min)
40
40
mA
V436616Y24V Rev. 1.0 January 2002
6