6.5.3 Smart Fan Control
Smart Fan Control provides two mechanisms. One is Thermal Cruise mode and the other is Fan
Speed Cruise mode.
6.5.3.1. Thermal Cruise mode
At this mode, W83L784R/G provides the Smart Fan system which can control the fan speed
automatically depend on current temperature to keep it with in a specific range. At first a wanted
temperature and interval must be set (ex. 55 °C ± 3 °C) by BIOS, as long as the current temperature
remains below the setting value, the fan will be off. Once the temperature exceeds the setting high
limit temperature (58°C), the fan will be turned on with a specific speed set by BIOS (ex: 80% duty
cycle) and automatically controlled its PWM duty cycle with the temperature varying. Three conditions
may occur:
(1) If the temperature still exceeds the high limit (ex: 58°C), PWM duty cycle will increase slowly. If the
fan has been operating in its fully speed but the temperature still exceeds the high limit (ex: 58°C), a
warning message or a fan_fault signal(pin5) will be issued to protect the system.
(2) If the temperature goes below the high limit (ex: 58°C), but above the low limit (ex: 52°C), the fan
speed will be fixed at the current speed because the temperature is in the target area (ex: 52 °C ~
58°C).
(3) If the temperature goes below the low limit (ex: 52°C), PWM duty cycle will decrease slowly to 0 or
a preset value until the temperature exceeds the low limit.
Figure 17 gives an illustration for Thermal Cruise Mode.
58`C
55`C
52`C
A
B
PWM 100
Duty
Cycle 50
0
Fan Start = 20%
C
D
Figure 17-1
- 16 -