M61040FP
Data Timing
Table 2
Establishment Data
Reset
Battery voltage output
Offset adjustment
Charge/discharge current detection
FET control
Multiplexer select
Conditioning circuit
Regulator over current control
Address
D5
D4
D3
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
Data
D2
D1
D0
Contents
—
—
—
—
—
— Refer to table 3
—
—
— Refer to table 4
—
—
— Refer to table 5
—
—
— Refer to table 6
—
—
— Refer to table 7
—
—
— Refer to table 8
—
—
— Refer to table 9
Table 3 Battery Voltage Output
D2
D1
D0
Output Voltage
0
0
0
V1
0
0
1
V2
0
1
0
V3
0
1
1
V4
1
0
0
Connect to VIN2
1
0
1
Connect to VIN3
1
1
0
Connect to VIN4
1
1
1
Connect to VIN10
Note: V1 battery voltage output when system reset
Detail
Offset voltage output
Offset voltage output
Offset voltage output
Offset voltage output
Table 4 Offset Voltage Control Section of Discharge Current Monitor Amplifier
D2
D1
D0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
Note: No offset voltage when system reset
Output
Offset Voltage Value
No offset (0 V)
1V
2.1 V
3.1 V
3.7 V
1V
1V
1V
Table 5 Charge and Discharge Current Detection
D2
D1
D0
Mode
0
0
0
AMP stop, resistor open
0
0
1
Gain × 40 output
0
1
0
Gain × 100 output
0
1
1
Gain × 200 output
1
0
0
AMP stop, resistor open
1
0
1
Offset output (× 40)
1
1
0
Offset output (× 100)
1
1
1
Offset output (× 200)
Note: Amplifier operation is stopped when system reset
Output
AMP operation stop, current save
AMP operation stop, current save
REJ03F0237-0200 Rev.2.00 Mar 18, 2008
Page 17 of 24