XE3005/XE3006
The CODEC bandwidth is around 100 Hz to 10 kHz at the nominal system frequency settings (MCLK = 5 MHz, CKDIV =
1, FSYNC = 20 kHz).
In digital loop back mode, the data entering into the Audio Interface is not transferred to the DAC. However, the
Sandman™ function (if activated) continues to output the SMDA signal based on the data entered into the Audio Interface
(input terminal SDI).
5 SPECIFICATIONS
5.1 ABSOLUTE MAXIMUM RATINGS
Stresses above those listed in the following table may cause permanent failure. Exposure to absolute ratings for
extended periods may affect device reliability.
The values are in accordance with the Absolute Maximum Rating System (IEC 134).
All voltages are referenced to ground (VSSA and VSSD).
Analog and digital grounds are equal (VSSA = VSSD).
Symbol
Parameter
Conditions
Min
Max
Unit
VDD Supply voltage
-0.3
3.65
V
Tstg Storage temperature
-65
150
°C
TA Operating free-air temperature, TA
-20
70
°C
Ves Electrostatic discharge protection
1)
500
V
Ilus Static latchup current
2)
10
98
mA
Vlud Dynamic latchup voltage
2)
50
V
1) Tested according MIL883C Method 3015.6, class JEDEC 1B (Standardized Human Body Model: 100 pF, 1500 Ω, 3
pulses, protection related to substrate).
2) Static and dynamic latchup values are valid at 27 °C.
5.2 RECOMMENDED OPERATING CONDITIONS
All voltages referenced to ground (VSSA and VSSD).
Supply voltage, VDD
Analog signal peak input voltage, AIN (gain = 20x)
Analog signal peak input voltage, AIN (gain = 5x)
Differential output load resistance
Master clock frequency
ADC or DAC conversion rate
Operating free-air temperature, TA
Min
Typ
1.8
3.0
16
32
1.024
20
-20
Max
Unit
3.6
V
65
mV
270
mV
Ohm
33
MHz
48
kHz
70
°C
© Semtech 2005
www.semtech.com
19