APPLICATION NOTE
PLCDA03C-6
thru
PLCDA15C-6
The PLCDAxxC-6 Series are low capacitance, bidirectional TVS arrays that are designed to protect I/O or high speed data lines from the damaging
effects of ESD or EFT. This product series has a surge capability of 500 Watts PPP per line for an 8/20µs waveshape and offers ESD protection >
40kv.
BIDIRECTIONAL COMMON-MODE CONFIGURATION (Figure 1)
Ideal for use multimode transceiver I/O lines, the PLCDAxxC-6 Series provides up
to six (6) lines of protection in a common-mode configuration as depicted in Figure
1.
Circuit connectivity is as follows:
Line 1 is connected to Pin 1.
Line 2 is connected to Pin 2.
Line 3 is connected to Pin 3.
Line 4 is connected to Pin 8.
Line 5 is connected to Pin 7.
Line 6 is connected to Pin 6.
Pins 4 and 5 are connected to Ground.
Figure 1: Typical Transceiver Protection Circuit
LINE 6
LINE 5
LINE 4
LINE 3
LINE 2
LINE 1
1
8
BIDIRECTIONAL COMMON-MODE CONFIGURATION (Figure 2)
The PLCDAxxC-6 Series also provides video line applications six (6) lines of
protection in a common-mode configuration as depicted in Figure 2.
Circuit connectivity is as follows:
Line 1 (Red) is connected to Pin 1.
Line 2 (Green) is connected to Pin 2.
Line 3 (Blue) is connected to Pin 3.
Line 4 (VSYNC) is connected to Pin 6.
Line 5 (HSYNC) is connected to Pin 7.
Pins 4 and 5 are connected to Ground.
CIRCUIT BOARD LAYOUT RECOMMENDATIONS
Circuit board layout is critical for Electromagnetic
Compatibility (EMC) protection. The following
guidelines are recommended:
The protection device should be placed near the
input terminals or connectors, the device will
divert the transient current immediately before it
can be coupled into the nearby traces.
The path length between the TVS device and
the protected line should be minimized.
All conductive loops including power and ground
loops should be minimized.
The transient current return path to ground
should be kept as short as possible to reduce
parasitic inductance.
Ground planes should be used whenever
possible. For multilayer PCBs, use ground vias.
2
7
3
6
4
5
Figure 2: Typical Video Line Protection Circuit
LINE 1 (RED)
LINE 2 (GREEN)
LINE 3 (BLUE)
4
3
2
1
5
6
7
8
LINE 4 (VSYNC)
LINE 4 (HSYNC)
DB-15
CONNECTOR
05102.R6 4/05
4
www.protekdevices.com