Philips Components
Desktop video & FM radio module
system M, N
Preliminary specification
FM1236
Environmental conditions
SYMBOL
PARAMETER
Non-operational conditions
Tamb
RH
ambient temperature
relative humidity
gB
bump acceleration
gS
shock acceleration
vibration amplitude
Operational conditions
Tamb
RH
ambient temperature
relative humidity
CONDITIONS
MIN.
TYP.
MAX.
UNIT
25 g
50 g
10 to 55 Hz
−25
−
+85
°C
−
−
100
%
−
−
245
m/s2
−
−
490
m/s2
−
0.35
−
mm
−10
−
−
−
+60
°C
95
%
OVERALL PERFORMANCE
Conditional data
Unless otherwise specified, all electrical values for Chapter “Overall performance” apply at the following conditions.
SYMBOL
Tamb
RH
VS
ZCVBS
ZIF
ZAF
tpr
ZS(AE)
PARAMETER
ambient temperature
relative humidity
supply voltage (tuner and IF section)
video output load impedance (DC)
2nd IF sound output load impedance (DC)
AF sound output load impedance
pre-heating time (+5 V at pin 24)
aerial source impedance (asymmetrical)
VALUE
25 ±5
60 ±15
5 ±0.125
75
0.5
100
10
75
UNIT
°C
%
V
Ω
kΩ
kΩ
minute
Ω
1997 Feb 03
6