DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

UWR-12/1250-D24A-C 查看數據表(PDF) - Unspecified

零件编号
产品描述 (功能)
生产厂家
UWR-12/1250-D24A-C Datasheet PDF : 13 Pages
First Prev 11 12 13
UWR Models
PART NUMBER STRUCTURE
U WR - 5 / 3000 - D48 A CT LX - C
Output Configuration:
U = Unipolar
Wide Range Input
Nominal Output Voltage:
1.2, 1.5, 1.8, 2.5, 3.3, 5, 12 or 15 Volts
Maximum Output Current
in mA
RoHS-6 Compliant*
Optional Functions
A-Series
High Reliability
Input Voltage Range:
D12 = 10-18 Volts (12V nominal)
D24 = 18-36 Volts (24V nominal)
D48 = 36-75 Volts (48V nominal)
*Note: Not all model number combinations may be available. Contact MPS.
Optional Functions
The A-Series 7-15W DC/DC Converters offer numerous electrical/ mechanical
options. Per the Ordering Guide on page 2, the trailing "A" (A-Series) in each
part number pertains to the base part number. Part-number suffixes are added
after the "A," indicating the selection of standard options. The resulting part
number is a "standard product" and is available to any customer desiring that
particular combination of options. As described below, selecting certain options
will result in the installation of additional pins in certain locations.
Suffix
Blank
T
C
CT
N
NT
L1
Description
No Vout Trim or On/Off Control functions added (no I/O pins
installed in the pin 3 and pin 5 positions). The pin length remains at
0.2 inches (5.08 mm).
Add a Vout Trim function on pin 5. No pin 3 installed.
Add an On/Off Control function on pin 3 (with positive polarity). No
pin 5 installed.
Add the On/Off Control function (with positive polarity) on pin 3 and
add the Vout trim function on pin 5.
Add an On/Off Control function on pin 3 with negative polarity. No
pin 5 installed.
Add the On/Off Control function with negative polarity on pin 3 and
add the Vout trim function on pin 5.
Trim the pin length to 0.110 ±0.010 inches (2.79 ±0.25mm). This
option requires a minimum order quantity.
Single Output, High-Density,
6 Amp/15 Watt DC/DC Converters
L2
Trim the pin length to 0.145 ±0.010 inches (3.68 ±0.25mm). This
option requires a minimum order quantity.
-C
RoHS-6 hazardous substance compliance (does not claim EU RoHS
exemption 7b, lead in solder).
* Note: Usage of consecutive "C" and "-C" designations is correct for some
models. Example: UWR-5/3000-D48AC-C
Adaptations
There are various additional configurations available on A-Series 7-15W DC/DCs.
Because designating each of them with a standard part-number suffix would
result in an unmanageable matrix of part numbers, such are designated by
MPS and assigned 5-digit "part-number suffixes.
UWR-3.3/4250-D48AT-30690
Standard product, 48VIN, 3.3VOUT/4.25A with a VOUT Trim function added in
the pin 3 position, with adapted current limit set point to 6.5A min. and with
removed Input Overvoltage Shutdown function.
UWR-5/3000-D48ACT-30770
UWR-5/3000-D48ACT-30770-Y (RoHS-5)
Standard product, 48VIN, 5VOUT/3A. On/Off Control function (positive polarity)
on pin 3, VOUT, Trim function added on pin 5. Adaptations: Trim equations are
Tyco/Lucent-compatible. Transformer isolation system has been enhanced to
meet the basic insulation requirements of UL60950-1/EN60950-1. I/O pins
are 25-mil-square Tyco/Lucent compatible. Shielded metal case is connected
to +VIN pin 1. Input Overvoltage Shutdown function has been removed.
UWR-3.3/4500-D48ANT
Standard UWR-3.3/4250-D48A, 48VIN, 3.3VOUT with slightly higher output
current (4.5A), negative on/off polarity control and a special competitive-
compatible trim.
UWR-3.3/4500-D48ANT accepts trim adjustments to ±10% of nominal VOUT
not to exceed 15W of maximum output power. Users should carefully consider
the amount of trim added since excessive positive trim may exceed the
overvoltage protection. Excessive negative trim may interfere with proper
regulation.
UWR-3.3/4500-D48ANST Special trim version. See page 5.
UWR-5/3000-D48ANSTHL2-Y
UWR-3.3/4500-D48ANTHL2-Y
Negative on/off polarity, special trim, conformal coating added, 3.68mm pin
length, RoHS-5 compliance (with lead). RoHS-5 compliance requires a sched-
uled quantity order. Not all RoHS-5 “-Y” models are available. Please contact
Product Marketing for further information.