DATA SHEET • SKY13330-397LF SP2T SWITCH
Table 3. SKY13330-397LF Electrical Specifications (Note 1)
(VBATT = 2.3 V to 4.8 V, CTRL = 0/1.65 V to 2.70 V, TOP = +25 °C, PIN = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise
Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
RF Specifications
Insertion loss
IL
RF1 to RF2/RF3:
0.1 to 1.0 GHz
1.0 to 2.2 GHz
2.2 to 2.5 GHz
2.5 to 5.0 GHz
5.0 to 6.0 GHz
0.30
0.35
dB
0.35
0.50
dB
0.35
0.50
dB
0.45
0.65
dB
0.60
0.80
dB
Isolation
Iso
RF1 to RF2/RF3:
0.1 to 1.0 GHz
40
42
dB
1.0 to 2.2 GHz
30
34
dB
2.2 to 2.5 GHz
30
33
dB
2.5 to 5.0 GHz
22
24
dB
5.0 to 6.0 GHz
18
21
dB
Return loss
|S11|
RF1 to RF2/RF3,
0.1 to 6.0 GHz
20
dB
0.1 dB Input Compression Point
3rd Order Intermodulation Distortion
IP0.1dB
IMD3
RF1 to RF2/RF3,
0.8 to 2.5 GHz
fFND = 1950 MHz
@ +20 dBm,
fBLK = 1760 MHz
@ –15 dBm
+38.5
dBm
–110
–105
dBm
Switching speed
Startup time (Note 2)
50% VCTL to 10/90% RF
“on” time
1.70
μs
50% VCTL to 90/10% RF
“off” time
1.24
μs
10/90% RF rise time
0.50
μs
90/10% RF fall time
1.00
μs
Shutdown state to any RF
2
μs
switch state
DC Specifications
Control voltage:
high
low
VCTL_HIGH
VCTL_LOW
1.65
2.7
V
0
0.4
V
Supply voltage
VBATT
2.3
4.8
V
Supply current
IBATT
VBATT = 2.3 to 4.8 V
37
μA
Control current
ICTRL
CTRL = 1.8 V
1
μA
Shutdown mode supply current
IOFF
ENABLE = 0 V,
7
μA
VBATT = 2.3 V to 4.8 V
Note 1: Performance is guaranteed only under the conditions listed in this Table.
Note 2: Startup time refers to the amount of time it takes for the switch to be fully operational when coming out of shutdown mode (EN = 0).
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
201407C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 17, 2012
3