DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MC3411A 查看數據表(PDF) - Unspecified

零件编号
产品描述 (功能)
生产厂家
MC3411A Datasheet PDF : 29 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
MC3401A/3411A
FUNCTIONAL DESCRIPTION
COMMANDS
Commands determine the display mode and status of MC3401A/3411A. A command is the first byte (b0 to b7)
inputted to MC3401A/3411A via the DIN Pin after STB Pin has changed from “HIGH” to “LOW” State. If for some
reason the STB Pin is set to “HIGH” while data or commands are being transmitted, the serial communication is
initialized, and the data/commands being transmitted are considered invalid.
COMMAND 1 : DISPLAY MODE SETTING COMMAND
MC3401A/3411A provides 8 display mode settings as shown in the diagram below: As stated earlier a command is
the first one byte (b0 to b7) transmitted to MC3401A/3411A via the DIN Pin when STB is “LOW”. However, for these
commands, the bits 5 to 6 (b4 to b5) are ignored, bits 7 & 8 (b6 to b7) are given a value of “0”.
The Display Mode Setting Commands determine the number of segments and grids to be used (1/4 to1/12 duty, 16
to 24 segments). When these commands are executed, the display is forcibly turned off, the key scanning stops. A
display command “ON” must be executed in order to resume display. If the same mode setting is selected, no
command execution is take place, therefore, nothing happens.
When Power is turned “ON”, the 12-digit, 16-segment modes is selected.
MSB
LSB
0
0
-
-
b3 b2 b1 b0
00 : COMMAND 1 Don’t Care
Display Mode Settings
0000 : 4Grid, 24 Segments
0001 : 5Grid, 23 Segments
0010 : 6Grid, 22 Segments
0011 : 7Grid, 21 Segments
0100 : 8Grid, 20 Segments
0101 : 9Grid, 19 Segments
0110 : 10Grid, 18 Segments
0111 : 11Grid, 17 Segments
1XXX : 12Grid, 16 Segments
February 28, 2013 Ver. 1.10
15/29

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]