B32651 ... B32656
High pulse (wound)
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V2/µs.
Note:
The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt values
Lead spacing
VR
V DC
VRMS
V AC
250
160
400
200
630
250
850
450
1000
250
500
1250
450
500
1600
500
600
700
2000
700
1000
10 mm
15 mm
dV/dt in V/µs
4000
200
300
400
975
1850
4500
5200
8000
22.5 mm
27.5 mm
37.5 mm
120
50
180
100
300
150
90
600
300
100
1150
600
140
2400
1000
210
7000
2300
200
7500
Please read Cautions and warnings and
Important notes at the end of this document.
Page 20 of 41