DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LBA110LSTR 查看數據表(PDF) - Clare Inc => IXYS

零件编号
产品描述 (功能)
生产厂家
LBA110LSTR
Clare
Clare Inc => IXYS Clare
LBA110LSTR Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
LBA110L
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Input Power Dissipation
Min Typ Max Units
-
- 1501 mW
Input Control Current
Peak (10ms)
-
- 50 mA
-
-1 A
Reverse Input Voltage
Total Power Dissipation
Isolation Voltage
Input to Output
Operational Temperature
Storage Temperature
-
-5 V
-
- 8002 mW
3750
-40
-40
-
- VRMS
- +85 °C
- +125 °C
Soldering Temperature
DIP Package
Flatpack/Surface Mount
Package
(10 Seconds Max.)
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
-
- +260 °C
-
- +220 °C
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for an extended period may degrade the device and effect
its reliability.
Electrical Characteristics
Parameter
Conditions
Symbol Min Typ Max
Output Characteristics @ 25°C
Load Voltage (Peak)
Load Current *(Continuous)
AC/DC Configuration
Peak Load Current
On-Resistance
AC/DC Configuration
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Load Current Limiting
Input Characteristics @ 25°C
-
-
10ms
IL=120mA
VL=350V
IF=5mA, VL=10V
IF=5mA, VL=10V
50V; f=1MHz
Form A only
VL
-
- 350
IL
-
- 120
ILPK
-
-
-
RON
-
23 35
ILEAK
-
-
1
TON
-
-
3
TOFF
-
-
3
COUT
-
25
-
ICL
130 170 210
Input Control Current
IL=Load Current
IF
5
-
50
Input Dropout Current
-
IF
0.4 0.7 -
Input Voltage Drop
IF=5mA
VF
0.9 1.2 1.4
Reverse Input Voltage
-
VR
-
-
5
Reverse Input Current
VR=5V
IR
-
-
10
Input to Output Capacitance
-
CI/O
-
3
-
Input to Output Isolation
-
VI/O
3750 -
-
*NOTE: If both poles operate simultaneously load current must be derated so as not to exceed the package power dissipation value.
Units
V
mA
mA
µA
ms
ms
pF
mA
mA
mA
V
V
µA
pF
VRMS
2
www.clare.com
Rev. 3

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]