Micrel, Inc.
KSZ9031RNX
Functional Description: 10/100/1000 Transceiver Features
Auto MDI/MDI-X
The Automatic MDI/MDI-X feature eliminates the need to determine whether to use a straight cable or a crossover cable
between the KSZ9031RNX and its link partner. This auto-sense function detects the MDI/MDI-X pair mapping from the
link partner, and assigns the MDI/MDI-X pair mapping of the KSZ9031RNX accordingly.
Table 1 shows the KSZ9031RNX 10/100/1000 pin configuration assignments for MDI/MDI-X pin mapping.
Table 1. MDI/MDI-X Pin Mapping
Pin (RJ-45 pair)
1000Base-T
MDI
100Base-TX
10Base-T
1000Base-T
MDI-X
100Base-TX
10Base-T
TXRXP/M_A (1,2)
A+/–
TX+/–
TX+/–
B+/–
RX+/–
RX+/–
TXRXP/M_B (3,6)
B+/–
RX+/–
RX+/–
A+/–
TX+/–
TX+/–
TXRXP/M_C (4,5)
C+/–
Not used
Not used
D+/–
Not used
Not used
TXRXP/M_D (7,8)
D+/–
Not used
Not used
C+/–
Not used
Not used
Auto MDI/MDI-X is enabled by default. It is disabled by writing a one to Register 1Ch, Bit [6]. MDI and MDI-X mode is set
by Register 1Ch, Bit [7] if Auto MDI/MDI-X is disabled.
An isolation transformer with symmetrical transmit and receive data paths is recommended to support Auto MDI/MDI-X.
Pair-Swap, Alignment, and Polarity Check
In 1000Base-T mode, the KSZ9031RNX
Detects incorrect channel order and automatically restores the pair order for the A, B, C, D pairs (four channels)
Supports 50±10ns difference in propagation delay between pairs of channels in accordance with the IEEE 802.3
standard, and automatically corrects the data skew so the corrected four pairs of data symbols are synchronized
Incorrect pair polarities of the differential signals are automatically corrected for all speeds.
Wave Shaping, Slew-Rate Control, and Partial Response
In communication systems, signal transmission encoding methods are used to provide the noise-shaping feature and to
minimize distortion and error in the transmission channel.
For 1000Base-T, a special partial-response signaling method is used to provide the band-limiting feature for the
transmission path.
For 100Base-TX, a simple slew-rate control method is used to minimize EMI.
For 10Base-T, pre-emphasis is used to extend the signal quality through the cable.
PLL Clock Synthesizer
The KSZ9031RNX generates 125MHz, 25MHz, and 10MHz clocks for system timing. Internal clocks are generated from
the external 25MHz crystal or reference clock.
May 14, 2015
19
Revision 2.2