CXD2460R
CTGRY: Electronic shutter control data
Detailed description
D12
to
D22
HSHUT
High-speed electronic shutter setting.
The value set here is the number of SUB pulses from FR to the next FR.
MSB
LSB
Function
D22 D21 D20 D19 D18 D17 D16 D15 D14 D13 D12 Number of SUB pulses setting
D23
to
Input "0".
D39
High-speed and low-speed electronic shutter can be used together. Therefore, the exposure time is as follows:
FR cycle × VSHUT + (fv – HSHUT) × HR cycle + 634/MCK frequency [Hz] = Exposure time [s]
(fv: Number of HR in 1FR)
– 17 –