CXD1961AQ
Sub address 13 (hex)
Sub address 14 (hex)
Sub address 15 (hex)
Sub address 16 (hex)
Sub address 17 (hex)
Write
Write
Write
Write
Write
TUN_DAT1
TUN_DAT2
TUN_DAT3
TUN_DAT4
TUN_DAT5
Tuner control data
Tuner control data
Tuner control data
Tuner control data
Tuner control data
(I2C bus mode)
Set TUNSEL = 0 and TUNEN = 1 in the register 0F (hex).
13 (hex): Tuner PLL IC slave address + 0 (write mode)
14 to 17 (hex): Write data (tuning parameter)
I2C bus starts write operation when data setting to register 17 (hex) is finished. In
case of no acknowledge from tuner PLL IC, NAK in the register 09 (hex)-A is set
to 1.
(3 wire mode)
Set TUNSEL = 1 and TUEN = 1 in the register 0F (hex). 28 bits data (register 13
to 15 (hex) and upper 4bit of the register 16 (hex)) are transmitted serially. To
start operation, dummy data setting to the register 17 (hex) is needed.
Refer to the reference circuit (5).
Sub address 18 (hex)
Sub address 19 (hex)
Sub address 1A (hex)
Write
Write
Write
SYM_RATE1
SYM_RATE2
SYM_RATE3
Control word for multi-rate oscillation
Control word for multi-rate oscillation
Control word for multi-rate oscillation
NCO23 to NCO0
(MSB) (LSB)
The relation between symbol rate and the control word of the NCO is:
NCO [23:0] = (symbol rate) × 222 ÷ (crystal frequency)
Ex.) Symbol rate 20MSPS crystal 32MHz
NCO [23:0] = 20 × 106 × 222 ÷ 32 × 10–6
= 2,621,440
= 221 + 219
NCO21 = NCO19 = 1, other = 0
– 25 –