NX25F640C
Table 3: Command Set for the NX25F640C Serial Flash Memory (3)
Command Name
Byte 1 Byte 2-3
Byte 4-5 or n-bytes
Sector and SRAM Read Commands
Transfer Sector to SRAM-0 (2)
Transfer Sector to SRAM-1 (2)
Read SRAM-0 (1)
Read SRAM-1 (1)
5CH
SA15:0
0000H 0000H ST15:0 (4)
5DH
SA15:0
0000H 0000H ST15:0 (4)
71H
BA15:0
00H
Read Data
73H
BA15:0
00H
Read Data
Sector and SRAM Write Commands
Write Enable (1)
Write Disable (1)
Write Sector using SRAM-0 (2)
Write Sector using SRAM-1 (2)
Write to SRAM-0 (1)
Write to SRAM-1 (1)
06H
04H
F6H
SA15:0
BA15:0 Write Data+00H
98H
SA15:0
BA15:0 Write Data+00H
72H
BA15:0
Write Data+00H
74H
BA15:0
Write Data+00H
Transfer and Refresh Commands
Transfer SRAM-0 to Sector (2)
Transfer SRAM-1 to Sector (2)
Transfer SRAM-0 to SRAM-1 (2)
Transfer SRAM-1 to SRAM-0 (2)
Refresh Sector using SRAM-0 (2)
Refresh Sector using SRAM-1 (2)
F6H
SA15:0
0000H
98H
SA15:0
0000H
92H
0000H
0000H 0000H
55H
0000H
0000H 0000H
58H
SA15:0
0000H 0000H
59H
SA15:0
0000H 0000H
Configuration and Status Commands
Read Device Information Sector (2)
Read Configuration Register (1)
Write Configuration Register (1)
Read Status Register (1)
Clear Power Down Bit (1)
Set Power Down Bit (1)
15H
0000H
BA15:0 0000H Ready/Busy Read Data
8CH
CF15:0
8AH
CF15:0
0000H
84H
ST15:0
09H
03H
Notes:
1. Command may be used when device is busy
2. Command may not be used when device is busy
3. Additional commands such as Auto Increment and other commands offering compatibility with earlier generation NexFlash
devices are available. Contact NexFlash for further information.
4. ST15:0 status repeats every 16 Clocks
NexFlash Technologies, Inc.
13
PRELIMINARY NXSF022F-0502
05/20/02 ©