DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DS1744WP120IND 查看數據表(PDF) - Maxim Integrated

零件编号
产品描述 (功能)
生产厂家
DS1744WP120IND
MaximIC
Maxim Integrated MaximIC
DS1744WP120IND Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
DS1744/DS1744P Y2K-Compliant, Nonvolatile Timekeeping RAMs
Table 1. Truth Table
VCC
CE OE WE
VIH
X
X
VCC > VPF
VIL
X
VIL
VIL
VIL
VIH
VIL
VIH
VIH
VSO < VCC < VPF
X
X
X
VCC < VSO < VPF
X
X
X
MODE
Deselect
Write
Read
Read
Deselect
Deselect
DQ
High-Z
Data In
Data Out
High-Z
High-Z
High-Z
POWER
Standby
Active
Active
Active
CMOS Standby
Data-Retention Mode
SETTING THE CLOCK
As shown in Table 2, bit 7 of the Control register is the W (write) bit. Setting the W bit to 1 halts updates
to the device registers. The user can subsequently load correct date and time values into all eight registers,
followed by a write cycle of 00h to the Control register to clear the W bit and transfer those new settings
into the clock, allowing timekeeping operations to resume from the new set point.
Again referring to Table 2, bit 6 of the Control register is the R (read) bit. Setting the R bit to 1 halts
updates to the device registers. The user can subsequently read the date and time values from the eight
registers without those contents possibly changing during those I/O operations. A subsequent write cycle
of 00h to the Control register to clear the R bit allows timekeeping operations to resume from the
previous set point.
The pre-existing contents of the Control register bits 0:5 (Century value) are ignored/unmodified by a
write cycle to Control if either the W or R bits are being set to 1 in that write operation.
The pre-existing contents of the Control register bits 0:5 (Century value) will be modified by a write
cycle to Control if the W bit is being cleared to 0 in that write operation.
The pre-existing contents of the Control register bits 0:5 (Century value) will not be modified by a write
cycle to Control if the R bit is being cleared to 0 in that write operation.
STOPPING AND STARTING THE CLOCK OSCILLATOR
The clock oscillator can be stopped at any time. To increase the shelf life, the oscillator can be turned off
to minimize current drain from the battery. The OSC bit is the MSB (bit 7) of the seconds registers (Table
2). Setting it to a 1 stops the oscillator.
FREQUENCY TEST BIT
As shown in Table 2, bit 6 of the day byte is the frequency test bit. When the frequency test bit is set to
logic 1 and the oscillator is running, the LSB of the seconds register toggles at 512Hz. When the seconds
register is being read, the DQ0 line toggles at the 512Hz frequency as long as conditions for access remain
valid (i.e., CE low, OE low, WE high, and address for seconds register remain valid and stable).
CLOCK ACCURACY (DIP MODULE)
The DS1744 is guaranteed to keep time accuracy to within ±1 minute per month at +25°C. The RTC is
calibrated at the factory by Maxim using nonvolatile tuning elements, and does not require additional
calibration. For this reason, methods of field clock calibration are not available and not necessary. Clock
accuracy is also affected by the electrical environment; caution should be taken to place the RTC in the
lowest-level EMI section of the PC board layout. For additional information, refer to Application Note 58.
5 of 16

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]