(10) When ambient temperature is lower than 10ºC may reduce the display quality. For example, the
response time will become slowly, and the starting voltage of CCFL will be higher than room
temperature.
11.2 SAFETY PRECAUTIONS
(1) The startup voltage of Backlight is approximately 1000 Volts. It may cause electrical shock while
assembling with inverter. Do not disassemble the module or insert anything into the Backlight unit.
(2) If the liquid crystal material leaks from the panel, it should be kept away from the eyes or mouth. In
case of contact with hands, skin or clothes, it has to be washed away thoroughly with soap.
(3) After the module’s end of life, it is not harmful in case of normal operation and storage.
11.3 SAFETY STANDARDS
The LCD module should be certified with safety regulations as follows:
(1) UL60950-1 or updated standard.
(2) IEC60950-1 or updated standard.
11.4. Storage
(1) Do not leave the module in high temperature, and high humidity for a long time.
It is highly recommended to store the module with temperature from 0to 35
And relative humidity of less than 70%
(2) Do not store the TFT – LCD module in direct sunlight
(3) The module should be stored in dark place. It is prohibited to apply sunlight or fluorescent light in storing
11.5. Operation condition guide
(1) The LCD product should be operated under normal condition.
Normal condition is defined as below :
Temperature : 20±15
Humidity: 65±20%
Display pattern : continually changing pattern(Not stationary)
(2) If the product will be used in extreme conditions such as high temperature , high humidity , high altitude ,
display pattern or operation time etc…It is strongly recommended to contact CMO for application
engineering advice . Otherwise , Its reliability and function may not be guaranteed.
11.6 OTHER
When fixed patterns are displayed for a long time, remnant image is likely to occur.